Drywall Temperature Calibrator: 32°F to 212°F /0°C to 100°C, 32°F to 212°F /0°C to 100°C
In Stock
$2,796.00
Save 7%
$2,586.88
/each
Earn 2586 points for this item
($25.86 for your next purchase!)
REGISTER NOW TO EARN!
Request quantity discount pricing
You're Viewing
TEL-TRU Drywall Temperature Calibrator: 32°F to 212°F...
Mfr # CSD-F83-320
$2,586.88
Customers Also Viewed
No related products found.
Product Details
| Brand | TEL-TRU |
| RTD Temperature Fahrenheit - Maximum | 212 Degrees F |
| Is this a Hazardous Material Product? | N |
| Voltage | 115V AC |
| For Stem Diameter | 0.150 in, 0.187 in, 0.125 in |
| Thermocouple Temperature Fahrenheit - Maximum | 212 Degrees F |
| Number of Inserts Included | 0 |
| Power Source | Plug-In |
| Manufacturer Part Number | CSD-F83-320 |
| Calibrator Weight | 9.5 lb |
| RTD Temperature Celsius - Minimum | 0 Degrees C |
| Interchangeable Insert | Yes |
| Single Well/Dual Well | Single Well |
| Sensor Technology | Thermistor |
| Storage Protection Code | A |
| Temperature Set Points | 160 Degrees F, 40 Degrees F, 214 Degrees F, 32 Degrees F |
| Overall Depth | 8.88 in |
| Stabilization Time | 3 min |
| Well Depth | 6 in |
| Stability | +/-0.2 Degrees F (0.1 Degrees C) |
| Product Powered by Fossil Fuel | N |
| Safety Data Sheet (SDS) Applicable? | N |
| Overall Height | 6.25 in |
| Thermocouple Temperature Range | 32 Degrees F to 212 Degrees F ; 0 Degrees C to 100 Degrees C |
| For Thermocouple Type | Type B, Type C, Type E, Type N, Type J, Type K, Type L, Type M, Type R, Type S, Type T |
| Display Sell UOM | EA |
| RoHS - Restricted Use of Hazardous Substances Directive (RoHS) | Y |
| Typical Uniformity | +/-0.03 Degrees F (0.02 Degrees C) for 20 Minutes |
| RTD Temperature Range | 32 Degrees F to 212 Degrees F ; 0 Degrees C to 100 Degrees C |
| Thermocouple Temperature Celsius - Minimum | 0 Degrees C |
| Typical Heating Time | 12 min (60 Degrees F to 32 Degrees F) |
| Should Sales be Restricted by Region? | N |
| Freight Class Code | 18 |
| Thermocouple Temperature Celsius - Maximum | 100 Degrees C |
| Display Qty | 1 |
| Typical Cooling Time | 12 min (60 Degrees F to 32 Degrees F) |
| RTD Temperature Celsius - Maximum | 100 Degrees C |
| Includes NIST-Traceable Certificate | Yes |
| Contains Volatile Organic Compounds (VOCs) | N |
| Overall Width | 8.75 in |
| Contains California Prop 65 Carcinogen | N |
| California Biodegradable Labeling Compliance | N |
| Thermocouple Temperature Fahrenheit - Minimum | 32 Degrees F |
| Contains California Prop 65 Reproductive Toxicant | N |
| Set Point Style | Fixed |
| RTD Temperature Fahrenheit - Minimum | 32 Degrees F |
| Number of Insert Holes | 3 |
| Insert Hole Diameter | 1 in |
| Well Diameter | 1 in |
| Calibration Certificate Type | NIST Traceable |
| Ozone Depleting Substance | N |
| Calibrator Accuracy | +/- .2F |
| Mfr. Model # | CSD-F83-320 |
Description
Drywall Temperature Calibrator, 6.25 in H