Digital Multimeter: Avg, CAT III 600V, 1, 000 V Max AC Volt Measurement, IP40
Digital Multimeter: Avg, CAT III 600V, 1, 000 V Max AC Volt Measurement, IP40

Product Image

Digital Multimeter: Avg, CAT III 600V, 1, 000 V Max AC Volt Measurement, IP40

Item 825MX0 Mfr. Model # FLUKE-15B+ ESP
In Stock
$169.00 /each
Earn 169 points with this purchase
Request quantity discount pricing
You're Viewing
Digital Multimeter: Avg, CAT III 600V, 1, 000 V Max AC Volt Measurement, IP40
FLUKE Digital Multimeter: Avg, CAT III 600V, 1, 000...
Item 825MX0
$169.00
Customers Also Viewed

No related products found.

Product Details

Brand FLUKE
EnvironmentallyPreferable_Indicator N
Current Leakage Testing No
Batteries Included Yes
Basic DC Voltage Accuracy 0.5% + 3
Maximum AC Current Measurement 10 A
Thermal Imaging No
Minimum Operating Temperature 32 Degrees F
Data Logging No
Maximum Capacitance Measurement 1,000 uF
Overall Depth 1.95 in
Minimum DC Voltage Measurement 4 V
Maximum DC Voltage Measurement 1,000 V
Removable Screen No
Resistance Measurement Accuracy +/-0.5% + 2 digits
Maximum AC Voltage Measurement 1,000 V
Display Type LCD
Freight Class Code 43
Intrinsically Safe No
DC Voltage Range 4 V to 1,000 V
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Battery Size AA
Basic DC Current Accuracy 1.5% + 3
Includes (2) Batteries, Test Leads (TL75)
Maximum Resistance Measurement 40 kiloohm
Minimum AC Voltage Measurement 4 V
Overall Height 7.2 in
Multimeter Style Compact
Features_Combined Non-Wireless Compatible ; Data Logging: No ; IP40 ; Intrinsically Safe: No ; Thermal Imaging: No ; Removable Screen: No
California Prop 65 Cancer N
California Prop 65 Reproductive Harm N
Duty Cycle Duty Cycle Test Included
Current Units mA, A
Parameters Measured DC Current, AC Current, AC Voltage, DC Voltage, Continuity, Capacitance, Resistance
Standards IEC 61010-1, IEC61010-2-030 CAT III 600 V, IEC 61326-1
AC Current Range 4 A to 10 A
AC Response Calculation Average
AC Voltage Range 4 V to 1,000 V
DC Current Range 4 A to 10 A
Instrument Counts 4,000
Basic AC Current Accuracy 1.5% + 3
Data Hold Yes
Maximum Storage Temperature 140 Degrees F
Minimum Resistance Measurement 400 ohm
Includes Auto Sensing No Auto Sensing Included
CAT Safety Rating CAT III 600V
Diode Test Yes
IP Rating IP40
AC Current Measurement Resolution 0.1 uA
Is this a Hazardous Material Product? N
Should Sales be Restricted by Region? N
Manufacturers Warranty Length 1 yr
Storage Protection Code A
Temperature Measurement Accuracy 2.0% +/-1 Degrees C
Ozone Depleting Substance N
Temperature Measurement Resolution 0.1 Degrees C
Audible Continuity Yes
Manufacturer Part Number FLUKE-15B+ ESP
Special Features White Backlight
Battery Voltage 1.5 V
Weight 1 lb
Features_Subhead Standard
California Biodegradable Labeling Compliance N
Overall Width 3.58 in
Maximum Frequency Measurement 100 kHz
Product Powered by Fossil Fuel N
DC Current Measurement Resolution 0.1 uA
Bluetooth Non-Wireless Compatible
Maximum DC Current Measurement 10 A
Minimum Temperature Measurement -67 Degrees F
Basic AC Voltage Accuracy 1.0% + 3
DC Voltage Measurement Resolution 0.001 V
Display Sell UOM EA
Fuse Access Yes
Minimum Storage Temperature -22 Degrees F
Safety Data Sheet (SDS) Applicable? N
Capacitance Measurement Accuracy +/-5.0% +5 digits
Calibration Certificate Included No Certification Included, Not Included
Frequency Measurement Resolution 0.01 Hz
Maximum Operating Temperature 104 Degrees F
Minimum AC Current Measurement 4 A
Resistance Measurement Resolution 0.1 ohm
Minimum Frequency Measurement 0.01 Hz
Display Qty 1
Minimum DC Current Measurement 4 A
Mfr. Model # FLUKE-15B+ ESP
Description

DigitalMultimeter, Compact, 10A, 1000VAC/DC