657-600-0865 | contact@KDdepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Gas-Fired Duct Furnace: 300, 000 BtuH Heating Capacity Input, 409 Stainless Steel, Bottom
Gas-Fired Duct Furnace: 300, 000 BtuH Heating Capacity Input, 409 Stainless Steel, Bottom

Product Image

Gas-Fired Duct Furnace: 300, 000 BtuH Heating Capacity Input, 409 Stainless Steel, Bottom

Item KD-0244899 Mfr. Model # 6RJZ0
In Stock
$7,979.00 /each
Earn 7979 points with this purchase
Request quantity discount pricing
You're Viewing
Gas-Fired Duct Furnace: 300, 000 BtuH Heating Capacity Input, 409 Stainless Steel, Bottom
DAYTON Gas-Fired Duct Furnace: 300, 000 BtuH Heating...
Item KD-0244899
$7,979.00
Customers Also Viewed

No related products found.

Product Details

Brand DAYTON
Display Sell UOM EA
Display Qty 1
Ignition Type Direct Spark
Features Clamshell Style Heat Exchanger
Flue Diameter 6 in
Primary Heat Exchanger Material 409 Stainless Steel
Gas Connection Type Male NPT
Product Powered by Fossil Fuel N
Manufacturer Part Number 6RJZ0
Gas Connection Size 3/4 in
Vent Type Power
Contains California Prop 65 Carcinogen N
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Indoor Air Discharge Height 19 in
Air Flow @ 80(F) Rise 2,700 cfm
CEC Title 20 MAEDbS Certified Y
Overall Height 36 in
Service Access Location Bottom
Ozone Depleting Substance N
Air Flow @ 65(F) Rise 3,300 cfm
Freight Class Code 19
Includes Additional Safety Features of Fan Time Delay, Air Flow Prove Switch, and Terminal Block Wiring
Frequency 60 Hz
Should Sales be Restricted by Region? N
Gas Connection Size, Gas Connection Type 3/4 in, Male NPT
Heating Capacity Input 300,000 BtuH
Indoor Air Discharge Width 34-3/4 in
Thermostat Included No
Is this a Hazardous Material Product? N
Storage Protection Code A
Heater Voltage 115 V AC
Maximum Amperage 1.9 A
Air Temperature Rise 30 Degrees F
CEC Title 20 Applicable Y
EnvironmentallyPreferable_Indicator N
Max. External SP 2.0" WC
Heating Method Fan Forced
Furnace Type Power Vented Separated Combustion
Burner Air Inlet Size 6 in
Contains California Prop 65 Reproductive Toxicant N
Manufacturers Warranty Length 1 yr
Safety Data Sheet (SDS) Applicable? N
CEC Title 20 Compliant? Y
Air Flow 7407 cfm
Fuel Type Natural Gas
Venting Vented
Required Air Flow 2,467 cfm
Heat Exchanger Gauge 20 ga
Overall Depth 40 in
Standards ETL Certified
Combustion Type Separated Combustion
Heating Capacity Output 240,000 BtuH
Mounting Height 8 ft
Overall Width 37-1/8 in
Mfr. Model # 6RJZ0
Description

Gas Fired Dct Furnace, 3/4" M NPT, 7407cfm

Catalog Page 0