657-600-0865 | contact@KDdepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Gas-Fired Duct Furnace: 250, 000 BtuH Heating Capacity Input, 409 Stainless Steel, Bottom
Gas-Fired Duct Furnace: 250, 000 BtuH Heating Capacity Input, 409 Stainless Steel, Bottom

Product Image

Gas-Fired Duct Furnace: 250, 000 BtuH Heating Capacity Input, 409 Stainless Steel, Bottom

Item KD-0244895 Mfr. Model # 6RJY9
In Stock
$7,528.00 /each
Earn 7528 points with this purchase
Request quantity discount pricing
You're Viewing
Gas-Fired Duct Furnace: 250, 000 BtuH Heating Capacity Input, 409 Stainless Steel, Bottom
DAYTON Gas-Fired Duct Furnace: 250, 000 BtuH Heating...
Item KD-0244895
$7,528.00
Customers Also Viewed

No related products found.

Product Details

Brand DAYTON
Air Temperature Rise 30 Degrees F
Furnace Type Power Vented Separated Combustion
Manufacturer Part Number 6RJY9
Heat Exchanger Gauge 20 ga
Manufacturers Warranty Length 1 yr
Heater Voltage 115 V AC
Heating Capacity Output 200,000 BtuH
Ozone Depleting Substance N
Safety Data Sheet (SDS) Applicable? N
Display Sell UOM EA
Maximum Amperage 1.9 A
Overall Width 31-5/8 in
Air Flow @ 65(F) Rise 3,000 cfm
Includes Additional Safety Features of Fan Time Delay, Air Flow Prove Switch, and Terminal Block Wiring
Freight Class Code 19
Flue Diameter 5 in
EnvironmentallyPreferable_Indicator N
Combustion Type Separated Combustion
Contains California Prop 65 Carcinogen N
Is this a Hazardous Material Product? N
Storage Protection Code A
Fuel Type Natural Gas
Ignition Type Direct Spark
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Service Access Location Bottom
Burner Air Inlet Size 5 in
Gas Connection Size 3/4 in
Max. External SP 1.96" WC
Thermostat Included No
Features Clamshell Style Heat Exchanger
Required Air Flow 2,056 cfm
CEC Title 20 Applicable Y
Overall Depth 40 in
Primary Heat Exchanger Material 409 Stainless Steel
Contains California Prop 65 Reproductive Toxicant N
Product Powered by Fossil Fuel N
Air Flow 6173 cfm
Air Flow @ 80(F) Rise 2,300 cfm
Gas Connection Size, Gas Connection Type 3/4 in, Male NPT
Vent Type Power
Heating Capacity Input 250,000 BtuH
Venting Vented
CEC Title 20 Compliant? Y
Indoor Air Discharge Width 29-1/4 in
Display Qty 1
CEC Title 20 MAEDbS Certified Y
Frequency 60 Hz
Overall Height 36 in
Should Sales be Restricted by Region? N
Mounting Height 8 ft
Gas Connection Type Male NPT
Heating Method Fan Forced
Standards ETL Certified
Indoor Air Discharge Height 19 in
Mfr. Model # 6RJY9
Description

Gas Fired Dct Furnace, 3/4" M NPT, 6173cfm

Catalog Page 0