Gas-Fired Duct Furnace: 250, 000 BtuH Heating Capacity Input, 409 Stainless Steel, Bottom
Gas-Fired Duct Furnace: 250, 000 BtuH Heating Capacity Input, 409 Stainless Steel, Bottom

Product Image

Gas-Fired Duct Furnace: 250, 000 BtuH Heating Capacity Input, 409 Stainless Steel, Bottom

Manufacturer: DAYTON
Mfr. Model # 6RJY9
In Stock
$7,528.00 Save 21%
$5,980.45 /each
Earn 5980 points for this item ($59.80 for your next purchase!) REGISTER NOW TO EARN!
Request quantity discount pricing
You're Viewing
Gas-Fired Duct Furnace: 250, 000 BtuH Heating Capacity Input, 409 Stainless Steel, Bottom
DAYTON Gas-Fired Duct Furnace: 250, 000 BtuH Heating...
Mfr # 6RJY9
$5,980.45
Customers Also Viewed

No related products found.

Product Details

Brand DAYTON
Thermostat Included No
Overall Height 36 in
CEC Title 20 Applicable Y
Heater Voltage 115 V AC
Indoor Air Discharge Width 29-1/4 in
Mounting Height 8 ft
Heating Capacity Input 250,000 BtuH
Product Powered by Fossil Fuel N
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Fuel Type Natural Gas
Air Flow 6173 cfm
Venting Vented
Manufacturers Warranty Length 1 yr
Storage Protection Code A
Furnace Type Power Vented Separated Combustion
Burner Air Inlet Size 5 in
Air Flow @ 80(F) Rise 2,300 cfm
CEC Title 20 Compliant? Y
Gas Connection Size, Gas Connection Type 3/4 in, Male NPT
Ozone Depleting Substance N
Standards ETL Certified
Should Sales be Restricted by Region? N
Freight Class Code 19
EnvironmentallyPreferable_Indicator N
Indoor Air Discharge Height 19 in
Air Temperature Rise 30 Degrees F
Combustion Type Separated Combustion
Display Sell UOM EA
Overall Depth 40 in
Frequency 60 Hz
Features Clamshell Style Heat Exchanger
Includes Additional Safety Features of Fan Time Delay, Air Flow Prove Switch, and Terminal Block Wiring
Contains California Prop 65 Carcinogen N
Manufacturer Part Number 6RJY9
Primary Heat Exchanger Material 409 Stainless Steel
Safety Data Sheet (SDS) Applicable? N
Gas Connection Size 3/4 in
Is this a Hazardous Material Product? N
Flue Diameter 5 in
Service Access Location Bottom
Contains California Prop 65 Reproductive Toxicant N
Ignition Type Direct Spark
Overall Width 31-5/8 in
Max. External SP 1.96" WC
Heat Exchanger Gauge 20 ga
Required Air Flow 2,056 cfm
Maximum Amperage 1.9 A
Heating Method Fan Forced
Gas Connection Type Male NPT
Heating Capacity Output 200,000 BtuH
Vent Type Power
Display Qty 1
Air Flow @ 65(F) Rise 3,000 cfm
CEC Title 20 MAEDbS Certified Y
Mfr. Model # 6RJY9
Description

Gas Fired Dct Furnace, 3/4" M NPT, 6173cfm

Catalog Page 0