Gas-Fired Duct Furnace: Power Vented, 160, 000 BtuH Heating Capacity Output, Side
Gas-Fired Duct Furnace: Power Vented, 160, 000 BtuH Heating Capacity Output, Side

Product Image

Gas-Fired Duct Furnace: Power Vented, 160, 000 BtuH Heating Capacity Output, Side

Manufacturer: DAYTON
Mfr. Model # 6RJX4
In Stock
$4,287.00 Save 20%
$3,412.04 /each
Earn 3412 points for this item ($34.12 for your next purchase!) REGISTER NOW TO EARN!
ETA 60-90 DAYS
Request quantity discount pricing
You're Viewing
Gas-Fired Duct Furnace: Power Vented, 160, 000 BtuH Heating Capacity Output, Side
DAYTON Gas-Fired Duct Furnace: Power Vented, 160, 00...
Mfr # 6RJX4
$3,412.04
Customers Also Viewed

No related products found.

Product Details

Brand DAYTON
Ozone Depleting Substance N
Gas Connection Type Male NPT
Gas Connection Size 1/2 in
Contains California Prop 65 Reproductive Toxicant N
CEC Title 20 MAEDbS Certified Y
Is this a Hazardous Material Product? N
Manufacturers Warranty Length 1 yr
Freight Class Code 18
EnvironmentallyPreferable_Indicator N
Burner Air Inlet Size 5 in
Mounting Height 8 ft
Flue Diameter 5 in
Primary Heat Exchanger Material 409 Stainless Steel
Ignition Type Direct Spark
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Air Temperature Rise [Number] 30 Degrees F
Overall Depth 37 in
Heating Capacity Input 200,000 BtuH
Air Flow 4938 cfm
Includes Additional Safety Features of Fan Time Delay, Air Flow Prove Switch, and Terminal Block Wiring
Heating Capacity Output 160,000 BtuH
Safety Data Sheet (SDS) Applicable? N
Standards ETL Certified
CEC Title 20 Applicable Y
Contains California Prop 65 Carcinogen N
Frequency 60 Hz
Heat Exchanger Gauge 20 ga
Service Access Location Side
Storage Protection Code A
Maximum Amperage 1.9 A
Overall Width 26-1/8 in
Venting Vented
Product Powered by Fossil Fuel N
Furnace Type Power Vented
Max. External SP 0.75" WC
Heating Method Fan Forced
Overall Height 37-3/4 in
Vent Type Power
Should Sales be Restricted by Region? N
Heater Voltage 115 V AC
Required Air Flow 1,852 cfm
Indoor Air Discharge Width 23-3/4 in
Air Flow @ 80(F) Rise 1,900 cfm
Fuel Type Natural Gas
Combustion Type Open Combustion
Indoor Air Discharge Height 19 in
Air Flow @ 65(F) Rise 2,300 cfm
CEC Title 20 Compliant? Y
Thermostat Included Thermostat Not Included
Mfr. Model # 6RJX4
Description

Gas Fired Dct Furnace, 1/2" M NPT, 4938cfm

Catalog Page 0