657-600-0865 | contact@KDdepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Gas-Fired Duct Furnace: 150, 000 BtuH Heating Capacity Input, 409 Stainless Steel, Side
Gas-Fired Duct Furnace: 150, 000 BtuH Heating Capacity Input, 409 Stainless Steel, Side

Product Image

Gas-Fired Duct Furnace: 150, 000 BtuH Heating Capacity Input, 409 Stainless Steel, Side

Item 6RJX3 Mfr. Model # 6RJX3
In Stock
$3,866.00 /each
Earn 3866 points with this purchase
Request quantity discount pricing
You're Viewing
Gas-Fired Duct Furnace: 150, 000 BtuH Heating Capacity Input, 409 Stainless Steel, Side
DAYTON Gas-Fired Duct Furnace: 150, 000 BtuH Heating...
Item 6RJX3
$3,866.00
Customers Also Viewed

No related products found.

Product Details

Brand DAYTON
Overall Height 37-3/4 in
Primary Heat Exchanger Material 409 Stainless Steel
Gas Connection Size 1/2 in
Air Flow @ 65(F) Rise 1,500 cfm
Combustion Type Open Combustion
Required Air Flow 1,389 cfm
California Prop 65 Reproductive Harm N
Freight Class Code 18
Frequency 60 Hz
Furnace Type Power Vented
CEC Title 20 Regulated Product? Y
Air Temperature Rise 30 Degrees F
CEC Title 20 Compliant? Y
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Manufacturer Part Number 6RJX3
Heating Method Fan Forced
Heat Exchanger Gauge 20 ga
Product Powered by Fossil Fuel N
Storage Protection Code A
Flue Diameter 4 in
Gas Connection Size, Gas Connection Type 1/2 in, Male NPT
Thermostat Included No
Heating Capacity Output 120,000 BtuH
Indoor Air Discharge Height 19 in
Air Flow @ 80(F) Rise 1,700 cfm
Ignition Type Direct Spark
Vent Type Power
Fuel Type Natural Gas
Ozone Depleting Substance N
Should Sales be Restricted by Region? N
Safety Data Sheet (SDS) Applicable? N
Standards ETL Certified
CEC Title 20 Part Number Registered in MAEDBS? Y
Venting Vented
Burner Air Inlet Size 5 in
Indoor Air Discharge Width 18-1/4 in
Manufacturers Warranty Length 1 yr
EnvironmentallyPreferable_Indicator N
Air Flow 3704 cfm
California Prop 65 Cancer N
Includes Additional Safety Features of Fan Time Delay, Air Flow Prove Switch, and Terminal Block Wiring
Heating Capacity Input 150,000 BtuH
Overall Depth 37 in
Is this a Hazardous Material Product? N
Features Clamshell Style Heat Exchanger
Heater Voltage 115 V AC
Service Access Location Side
Max. External SP 0.75" WC
Gas Connection Type Male NPT
Maximum Amperage 1.9 A
Display Qty 1
Display Sell UOM EA
Overall Width 20-5/8 in
Mounting Height 8 ft
Mfr. Model # 6RJX3
Description

Gas Fired Dct Furnace, 1/2" M NPT, 3704cfm

Catalog Page 0