657-600-0865 | contact@KDdepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Gas-Fired Duct Furnace: 300, 000 BtuH Heating Capacity Input, Aluminized Steel, Side
Gas-Fired Duct Furnace: 300, 000 BtuH Heating Capacity Input, Aluminized Steel, Side

Product Image

Gas-Fired Duct Furnace: 300, 000 BtuH Heating Capacity Input, Aluminized Steel, Side

Item 6RJW9 Mfr. Model # 6RJW9
In Stock
$4,856.00 /each
Earn 4856 points with this purchase
Request quantity discount pricing
You're Viewing
Gas-Fired Duct Furnace: 300, 000 BtuH Heating Capacity Input, Aluminized Steel, Side
DAYTON Gas-Fired Duct Furnace: 300, 000 BtuH Heating...
Item 6RJW9
$4,856.00
Customers Also Viewed

No related products found.

Product Details

Brand DAYTON
Air Flow @ 65(F) Rise 3,300 cfm
Ignition Type Direct Spark
Burner Air Inlet Size 6 in
Display Sell UOM EA
Freight Class Code 18
Frequency 60 Hz
Heating Capacity Output 240,000 BtuH
Combustion Type Open Combustion
Heater Voltage 115 V AC
Heating Capacity Input 300,000 BtuH
Air Flow 7407 cfm
Product Powered by Fossil Fuel N
Storage Protection Code A
Ozone Depleting Substance N
EnvironmentallyPreferable_Indicator N
Fuel Type Natural Gas
CEC Title 20 Regulated Product? Y
Required Air Flow 2,778 cfm
Max. External SP 0.9" WC
Vent Type Power
Standards ETL Certified
Air Temperature Rise 30 Degrees F
Safety Data Sheet (SDS) Applicable? N
Air Flow @ 80(F) Rise 2,700 cfm
Includes Additional Safety Features of Fan Time Delay, Air Flow Prove Switch, and Terminal Block Wiring
Gas Connection Size 3/4 in
Features Clamshell Style Heat Exchanger
Overall Height 37-3/4 in
Mounting Height 8 ft
Indoor Air Discharge Width 34-3/4 in
CEC Title 20 Part Number Registered in MAEDBS? Y
Display Qty 1
CEC Title 20 Compliant? Y
Heating Method Fan Forced
California Prop 65 Reproductive Harm N
Primary Heat Exchanger Material Aluminized Steel
Is this a Hazardous Material Product? N
California Prop 65 Cancer N
Manufacturers Warranty Length 1 yr
Should Sales be Restricted by Region? N
Gas Connection Type Male NPT
Overall Width 37-1/8 in
Thermostat Included No
Furnace Type Power Vented
Heat Exchanger Gauge 20 ga
Overall Depth 37 in
Manufacturer Part Number 6RJW9
Flue Diameter 6 in
Service Access Location Side
Indoor Air Discharge Height 19 in
Venting Vented
Gas Connection Size, Gas Connection Type 3/4 in, Male NPT
Maximum Amperage 1.9 A
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Mfr. Model # 6RJW9
Description

Gas Fired Dct Furnace, 3/4" M NPT, 7407cfm

Catalog Page 0