Gas-Fired Duct Furnace: 250, 000 BtuH Heating Capacity Input, Aluminized Steel, Side
Gas-Fired Duct Furnace: 250, 000 BtuH Heating Capacity Input, Aluminized Steel, Side

Product Image

Gas-Fired Duct Furnace: 250, 000 BtuH Heating Capacity Input, Aluminized Steel, Side

Item KD-0244929 Mfr. Model # 6RJW8
In Stock
$4,129.00 /each
Earn 4129 points with this purchase
Request quantity discount pricing
You're Viewing
Gas-Fired Duct Furnace: 250, 000 BtuH Heating Capacity Input, Aluminized Steel, Side
DAYTON Gas-Fired Duct Furnace: 250, 000 BtuH Heating...
Item KD-0244929
$4,129.00
Customers Also Viewed

No related products found.

Product Details

Brand DAYTON
Air Flow 6173 cfm
Overall Depth 37 in
Storage Protection Code A
Air Flow @ 65(F) Rise 3,000 cfm
Heating Capacity Output 200,000 BtuH
Should Sales be Restricted by Region? N
Contains California Prop 65 Reproductive Toxicant N
Venting Vented
Thermostat Included No
Is this a Hazardous Material Product? N
Frequency 60 Hz
Heating Capacity Input 250,000 BtuH
Product Powered by Fossil Fuel N
Indoor Air Discharge Height 19 in
Air Flow @ 80(F) Rise 2,300 cfm
Flue Diameter 5 in
Gas Connection Size, Gas Connection Type 3/4 in, Male NPT
CEC Title 20 Compliant? Y
Standards ETL Certified
Manufacturer Part Number 6RJW8
Mounting Height 8 ft
Overall Height 37-3/4 in
Service Access Location Side
Freight Class Code 18
Furnace Type Power Vented
Maximum Amperage 1.9 A
CEC Title 20 MAEDbS Certified Y
Display Sell UOM EA
Primary Heat Exchanger Material Aluminized Steel
Includes Additional Safety Features of Fan Time Delay, Air Flow Prove Switch, and Terminal Block Wiring
Combustion Type Open Combustion
Manufacturers Warranty Length 1 yr
Max. External SP 0.9" WC
Features Clamshell Style Heat Exchanger
Overall Width 31-5/8 in
Indoor Air Discharge Width 29-1/4 in
Gas Connection Size 3/4 in
Heat Exchanger Gauge 20 ga
Heater Voltage 115 V AC
Ignition Type Direct Spark
Safety Data Sheet (SDS) Applicable? N
Contains California Prop 65 Carcinogen N
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Required Air Flow 2,315 cfm
Air Temperature Rise 30 Degrees F
Vent Type Power
Display Qty 1
CEC Title 20 Applicable Y
Gas Connection Type Male NPT
Fuel Type Natural Gas
EnvironmentallyPreferable_Indicator N
Burner Air Inlet Size 5 in
Heating Method Fan Forced
Ozone Depleting Substance N
Mfr. Model # 6RJW8
Description

Gas Fired Dct Furnace, 3/4" M NPT, 6173cfm

Catalog Page 0