657-600-0865 | contact@KDdepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Gas-Fired Duct Furnace: 100, 000 BtuH Heating Capacity Input, Aluminized Steel, Side
Gas-Fired Duct Furnace: 100, 000 BtuH Heating Capacity Input, Aluminized Steel, Side

Product Image

Gas-Fired Duct Furnace: 100, 000 BtuH Heating Capacity Input, Aluminized Steel, Side

Item 6RJW5 Mfr. Model # 6RJW5
In Stock
$3,172.00 /each
Earn 3172 points with this purchase
Request quantity discount pricing
You're Viewing
Gas-Fired Duct Furnace: 100, 000 BtuH Heating Capacity Input, Aluminized Steel, Side
DAYTON Gas-Fired Duct Furnace: 100, 000 BtuH Heating...
Item 6RJW5
$3,172.00
Customers Also Viewed

No related products found.

Product Details

Brand DAYTON
Primary Heat Exchanger Material Aluminized Steel
Should Sales be Restricted by Region? N
Combustion Type Open Combustion
Indoor Air Discharge Width 15-1/2 in
Fuel Type Natural Gas
Max. External SP 0.9" WC
Gas Connection Size, Gas Connection Type 1/2 in, Male NPT
Display Sell UOM EA
Mounting Height 8 ft
Features Clamshell Style Heat Exchanger
Indoor Air Discharge Height 19 in
Ozone Depleting Substance N
Ignition Type Direct Spark
Safety Data Sheet (SDS) Applicable? N
Maximum Amperage 1.9 A
Gas Connection Type Male NPT
Is this a Hazardous Material Product? N
CEC Title 20 Compliant? Y
Vent Type Power
Overall Depth 37 in
Includes Additional Safety Features of Fan Time Delay, Air Flow Prove Switch, and Terminal Block Wiring
Manufacturer Part Number 6RJW5
Freight Class Code 18
Heating Capacity Output 80,000 BtuH
Furnace Type Power Vented
Storage Protection Code A
Air Flow @ 65(F) Rise 1,100 cfm
California Prop 65 Cancer N
CEC Title 20 Regulated Product? Y
Venting Vented
Frequency 60 Hz
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Service Access Location Side
Gas Connection Size 1/2 in
Air Flow 2469 cfm
Manufacturers Warranty Length 1 yr
Burner Air Inlet Size 5 in
Standards ETL Certified
California Prop 65 Reproductive Harm N
Product Powered by Fossil Fuel N
Required Air Flow 929 cfm
Heating Method Fan Forced
Heater Voltage 115 V AC
Air Flow @ 80(F) Rise 1,000 cfm
Overall Height 37-3/4 in
Display Qty 1
Flue Diameter 4 in
Heat Exchanger Gauge 20 ga
CEC Title 20 Part Number Registered in MAEDBS? Y
EnvironmentallyPreferable_Indicator N
Overall Width 17-7/8 in
Thermostat Included No
Heating Capacity Input 100,000 BtuH
Air Temperature Rise 30 Degrees F
Mfr. Model # 6RJW5
Description

Gas Fired Dct Furnace, 1/2" M NPT, 2469cfm

Catalog Page 0