657-600-0865 | contact@KDdepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Gas-Fired Duct Furnace: 350, 000 BtuH Heating Capacity Input, Aluminized Steel, Bottom, 30°F
Gas-Fired Duct Furnace: 350, 000 BtuH Heating Capacity Input, Aluminized Steel, Bottom, 30°F

Product Image

Gas-Fired Duct Furnace: 350, 000 BtuH Heating Capacity Input, Aluminized Steel, Bottom, 30°F

Item KD-0244911 Mfr. Model # 6RJV6
In Stock
$5,178.00 /each
Earn 5178 points with this purchase
Request quantity discount pricing
You're Viewing
Gas-Fired Duct Furnace: 350, 000 BtuH Heating Capacity Input, Aluminized Steel, Bottom, 30°F
DAYTON Gas-Fired Duct Furnace: 350, 000 BtuH Heating...
Item KD-0244911
$5,178.00
Customers Also Viewed

No related products found.

Product Details

Brand DAYTON
Overall Depth 37 in
Gas Connection Size 3/4 in
Maximum Amperage 1.9 A
Overall Height 37-3/4 in
Gas Connection Size, Gas Connection Type 3/4 in, Male NPT
Ozone Depleting Substance N
Air Flow @ 65(F) Rise 4,000 cfm
Should Sales be Restricted by Region? N
Combustion Type Open Combustion
Gas Connection Type Male NPT
Manufacturer Part Number 6RJV6
Air Temperature Rise 30 Degrees F
Air Flow @ 80(F) Rise 3,200 cfm
Storage Protection Code A
Indoor Air Discharge Height 19 in
Vent Type Power
EnvironmentallyPreferable_Indicator N
CEC Title 20 Applicable Y
Is this a Hazardous Material Product? N
Display Sell UOM EA
Display Qty 1
Freight Class Code 18
Max. External SP 0.9" WC
Primary Heat Exchanger Material Aluminized Steel
Required Air Flow 3,241 cfm
Heating Capacity Input 350,000 BtuH
Includes Additional Safety Features of Fan Time Delay, Air Flow Prove Switch, and Terminal Block Wiring
Air Flow 8642 cfm
Manufacturers Warranty Length 1 yr
Thermostat Included No
Product Powered by Fossil Fuel N
Safety Data Sheet (SDS) Applicable? N
Burner Air Inlet Size 6 in
Contains California Prop 65 Reproductive Toxicant N
Heating Method Fan Forced
Fuel Type Natural Gas
Flue Diameter 6 in
Furnace Type Power Vented
Ignition Type Direct Spark
Heating Capacity Output 280,000 BtuH
Frequency 60 Hz
Contains California Prop 65 Carcinogen N
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Standards ETL Certified
Indoor Air Discharge Width 40-1/4 in
Service Access Location Bottom
Venting Vented
CEC Title 20 Compliant? Y
Heater Voltage 115 V AC
Overall Width 42-5/8 in
Features Clamshell Style Heat Exchanger
CEC Title 20 MAEDbS Certified Y
Mounting Height 8 ft
Heat Exchanger Gauge 20 ga
Mfr. Model # 6RJV6
Description

Gas Fired Dct Furnace, 3/4" M NPT, 8642cfm

Catalog Page 0