657-600-0865 | support@kddepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Gas-Fired Duct Furnace: Power Vented, 200, 000 BtuH Heating Capacity Output, Bottom
Gas-Fired Duct Furnace: Power Vented, 200, 000 BtuH Heating Capacity Output, Bottom

Product Image

Gas-Fired Duct Furnace: Power Vented, 200, 000 BtuH Heating Capacity Output, Bottom

Manufacturer: DAYTON
Mfr. Model # 6RJV4
In Stock
$4,129.00 Save 20%
$3,286.34 /each
Earn 3286 points for this item ($32.86 for your next purchase!) REGISTER NOW TO EARN!
ETA 60-90 DAYS
Request quantity discount pricing
You're Viewing
Gas-Fired Duct Furnace: Power Vented, 200, 000 BtuH Heating Capacity Output, Bottom
DAYTON Gas-Fired Duct Furnace: Power Vented, 200, 00...
Mfr # 6RJV4
$3,286.34
Customers Also Viewed

No related products found.

Product Details

Brand DAYTON
Gas Connection Size 3/4 in
Contains California Prop 65 Carcinogen N
Heating Method Fan Forced
Mounting Height 8 ft
Product Powered by Fossil Fuel N
Air Flow @ 80(F) Rise 2,300 cfm
Service Access Location Bottom
Air Flow @ 65(F) Rise 3,000 cfm
Vent Type Power
Gas Connection Type Male NPT
Combustion Type Open Combustion
Freight Class Code 18
CEC Title 20 Compliant? Y
Primary Heat Exchanger Material Aluminized Steel
Flue Diameter 5 in
Ozone Depleting Substance N
Manufacturers Warranty Length 1 yr
CEC Title 20 MAEDbS Certified Y
Maximum Amperage 1.9 A
Heating Capacity Output 200,000 BtuH
EnvironmentallyPreferable_Indicator N
Heating Capacity Input 250,000 BtuH
Heater Voltage 115 V AC
CEC Title 20 Applicable Y
Includes Additional Safety Features of Fan Time Delay, Air Flow Prove Switch, and Terminal Block Wiring
Air Temperature Rise [Number] 30 Degrees F
Is this a Hazardous Material Product? N
Should Sales be Restricted by Region? N
Frequency 60 Hz
Furnace Type Power Vented
Indoor Air Discharge Width 29-1/4 in
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Overall Depth 37 in
Overall Width 31-5/8 in
Indoor Air Discharge Height 19 in
Storage Protection Code A
Overall Height 37-3/4 in
Thermostat Included Thermostat Not Included
Contains California Prop 65 Reproductive Toxicant N
Burner Air Inlet Size 5 in
Heat Exchanger Gauge 20 ga
Ignition Type Direct Spark
Safety Data Sheet (SDS) Applicable? N
Air Flow 6173 cfm
Max. External SP 0.9" WC
Venting Vented
Fuel Type Natural Gas
Required Air Flow 2,315 cfm
Standards ETL Certified
Mfr. Model # 6RJV4
Description

Gas Fired Dct Furnace, 3/4" M NPT, 6173cfm

Catalog Page 0