Gas-Fired Duct Furnace: 200, 000 BtuH Heating Capacity Input, Aluminized Steel, Bottom
Gas-Fired Duct Furnace: 200, 000 BtuH Heating Capacity Input, Aluminized Steel, Bottom

Product Image

Gas-Fired Duct Furnace: 200, 000 BtuH Heating Capacity Input, Aluminized Steel, Bottom

Item 6RJV3 Mfr. Model # 6RJV3
In Stock
$3,659.00 /each
Earn 3659 points with this purchase
Request quantity discount pricing
You're Viewing
Gas-Fired Duct Furnace: 200, 000 BtuH Heating Capacity Input, Aluminized Steel, Bottom
DAYTON Gas-Fired Duct Furnace: 200, 000 BtuH Heating...
Item 6RJV3
$3,659.00
Customers Also Viewed

No related products found.

Product Details

Brand DAYTON
California Prop 65 Cancer N
Ozone Depleting Substance N
Vent Type Power
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Flue Diameter 5 in
Heating Capacity Input 200,000 BtuH
Indoor Air Discharge Width 23-3/4 in
Indoor Air Discharge Height 19 in
Service Access Location Bottom
Manufacturers Warranty Length 1 yr
Display Qty 1
Heating Capacity Output 160,000 BtuH
Primary Heat Exchanger Material Aluminized Steel
Burner Air Inlet Size 5 in
Freight Class Code 18
Furnace Type Power Vented
Air Flow 4938 cfm
Heater Voltage 115 V AC
Product Powered by Fossil Fuel N
EnvironmentallyPreferable_Indicator N
Overall Depth 37 in
Ignition Type Direct Spark
Max. External SP 0.75" WC
Standards ETL Certified
Mounting Height 8 ft
Gas Connection Type Male NPT
Should Sales be Restricted by Region? N
Combustion Type Open Combustion
Heat Exchanger Gauge 20 ga
CEC Title 20 Regulated Product? Y
Required Air Flow 1,852 cfm
Venting Vented
Overall Width 26-1/8 in
Air Flow @ 65(F) Rise 2,300 cfm
CEC Title 20 Compliant? Y
Includes Additional Safety Features of Fan Time Delay, Air Flow Prove Switch, and Terminal Block Wiring
Is this a Hazardous Material Product? N
Air Temperature Rise 30 Degrees F
Gas Connection Size 1/2 in
Overall Height 37-3/4 in
Manufacturer Part Number 6RJV3
Safety Data Sheet (SDS) Applicable? N
Features Clamshell Style Heat Exchanger
Frequency 60 Hz
Air Flow @ 80(F) Rise 1,900 cfm
Fuel Type Natural Gas
Heating Method Fan Forced
Storage Protection Code A
California Prop 65 Reproductive Harm N
CEC Title 20 Part Number Registered in MAEDBS? Y
Display Sell UOM EA
Gas Connection Size, Gas Connection Type 1/2 in, Male NPT
Thermostat Included No
Maximum Amperage 1.9 A
Mfr. Model # 6RJV3
Description

Gas Fired Dct Furnace, 1/2" M NPT, 4938cfm

Catalog Page 0