Digital Clamp Meter: TRMS, CAT III 1000V/CAT IV 600V, 200 A Max AC Current Measurement
In Stock
$511.00
Save 35%
$334.12
/each
Earn 334 points with this purchase
Request quantity discount pricing
You're Viewing
FLUKE Digital Clamp Meter: TRMS, CAT III 1000V/CAT...
Item 60UN27
$334.12
Customers Also Viewed
No related products found.
Product Details
| Catalog Page | 519 |
| Brand | FLUKE |
| Current Leakage Testing | No |
| Frequency Measurement Accuracy | +/-(1 % + 2 counts) |
| Audible Continuity | Yes |
| DC Voltage Range | 1 V to 1,000 V |
| Minimum Resistance Measurement | 1 ohm |
| Battery Access | Yes |
| Basic AC Voltage Accuracy | FieldSense: +/-(3 % + 3 counts) 45 Hz - 66 HzLeads: +/-(1.5 % + 2 counts) 45 Hz - 66 Hz |
| Removable Screen | No |
| Features | FieldSense Technology |
| Calibration Certificate Included | No Certification Included, Not Included |
| AC Response Calculation | TRMS |
| Batteries Included | Yes |
| Includes Auto Sensing | No Auto Sensing Included |
| Maximum AC Voltage Measurement | 1,000 V |
| Should Sales be Restricted by Region? | N |
| Jaw Style | Open |
| Standards | CE, IEC 61010-2-032, CSA |
| Product Powered by Fossil Fuel | N |
| Safety Data Sheet (SDS) Applicable? | N |
| Maximum Conductor Size | 4/0 AWG |
| RoHS - Restricted Use of Hazardous Substances Directive (RoHS) | N |
| Maximum Storage Temperature | 140 Degrees F |
| Bluetooth | No |
| California Prop 65 Reproductive Harm | N |
| Inrush | No |
| Minimum Operating Temperature | 14 Degrees F |
| Bar Graph Included | No |
| Display Sell UOM | EA |
| Features_Combined | Data Logging: Yes ; Intrinsically Safe: No ; Thermal Imaging: No ; DC Voltage, Data Logging: Yes ; Intrinsically Safe: No ; Thermal Imaging: No ; Frequency, Data Logging: Yes ; Intrinsically Safe: No ; Thermal Imaging: No ; AC Current, Data Logging: Yes ; Intrinsically Safe: No ; Thermal Imaging: No ; AC Voltage, Data Logging: Yes ; Intrinsically Safe: No ; Thermal Imaging: No ; Resistance |
| Maximum Resistance Measurement | 20 kiloohm |
| Data Logging | Yes |
| Auto Power Off | Yes |
| Display Qty | 1 |
| Maximum Operating Temperature | 122 Degrees F |
| AC Current Measurement Resolution | 0.1 A |
| Jaw Opening | 0.7 in |
| AC Current Range | 0.1 A to 200 A |
| AC Voltage Measurement Resolution | 1 V |
| CAT Safety Rating | CAT III 1000V, CAT IV 600V |
| Manufacturers Warranty Length | 2 yr |
| Storage Protection Code | A |
| Minimum AC Current Measurement | 0.1 A |
| Includes | Alligator Clips (AC285), H-T6 Holster, Attached Test Leads with Removable 4 mm Probe Caps |
| Thermal Imaging | No |
| Freight Class Code | 18 |
| Auto Ranging | Yes |
| Frequency Measurement Resolution | 1 Hz |
| Basic AC Current Accuracy | +/-(3 % + 3 counts) 45 Hz - 66 Hz |
| Battery Size | AA |
| Peak Hold | No |
| Midscale Resistance | 10 kiloohm |
| Ozone Depleting Substance | N |
| Features_Subhead | Data Logging |
| Is this a Hazardous Material Product? | N |
| Manufacturer Part Number | T6-1000 PRO |
| Minimum DC Voltage Measurement | 1 V |
| California Prop 65 Cancer | N |
| Jaw Detachability | Fixed |
| Non-Contact Voltage Detector | Yes |
| Intrinsically Safe | No |
| AC Voltage Range | 1 V to 1,000 V |
| Resistance Measurement Resolution | 1 ohm |
| Data Hold | Yes |
| Display Type | Backlit LCD |
| Maximum DC Voltage Measurement | 1,000 V |
| Resistance Measurement Accuracy | +/-(1 % + 2 counts) |
| Minimum AC Voltage Measurement | 1 V |
| Digital/Analog | Digital |
| Diode Test | No |
| Parameters Measured | AC Current, AC Voltage, Frequency, DC Voltage, Resistance |
| Maximum AC Current Measurement | 200 A |
| Basic DC Voltage Accuracy | +/-(1 % + 2 counts) |
| California Biodegradable Labeling Compliance | N |
| DC Voltage Measurement Resolution | 1 V |
| Mfr. Model # | T6-1000 PRO |
Description