657-600-0865 | contact@KDdepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Thermometer Calibrator: -13°F to 284°F /-25°C to 140°C, -13°F to 284°F /-25°C to 250°C
Thermometer Calibrator: -13°F to 284°F /-25°C to 140°C, -13°F to 284°F /-25°C to 250°C

Product Image

Thermometer Calibrator: -13°F to 284°F /-25°C to 140°C, -13°F to 284°F /-25°C to 250°C

Item 54DD55 Mfr. Model # 7109A-P-156
In Stock
$19,792.00 /each
Earn 19792 points with this purchase
Request quantity discount pricing
You're Viewing
Thermometer Calibrator: -13°F to 284°F /-25°C to 140°C, -13°F to 284°F /-25°C to 250°C
FLUKE Thermometer Calibrator: -13°F to 284°F /-25°C...
Item 54DD55
$19,792.00
Customers Also Viewed

No related products found.

Product Details

Catalog Page 572
Brand FLUKE
California Prop 65 Cancer N
Is this a Hazardous Material Product? N
Standards FDA, ISO
Safety Data Sheet (SDS) Applicable? N
RTD Temperature Fahrenheit - Maximum 284 Degrees F
Voltage 24 V DC
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Typical Settling Time 10 min
Ozone Depleting Substance N
EnvironmentallyPreferable_Indicator N
Typical Heating Time 55 min (25 Degrees to 140 Degrees C), 35 min (-25 Degrees to 25 Degrees C)
Typical Cooling Time 75 min (25 Degrees to -25 Degrees C), 45 min (140 Degrees to 25 Degrees C)
Should Sales be Restricted by Region? N
Thermocouple Temperature Celsius - Maximum 250 Degrees C
Process Connections Included RTD, Thermocouple, Transmitter, Reference PRT
RTD Temperature Celsius - Maximum 140 Degrees C
Overall Height 15 in
Thermocouple Temperature Fahrenheit - Minimum -13 Degrees F
RTD Temperature Celsius - Minimum -25 Degrees C
Power Source Loop Power
RTD Temperature Fahrenheit - Minimum -13 Degrees F
Stability 0.01 Degrees C
Repeatability 0.04 Degrees C
Overall Width 9.5 in
California Prop 65 Reproductive Harm N
Calibrator Weight 44 lb
Display Sell UOM EA
Interface RS-232
Display Qty 1
Overall Depth 15.4 in
Common Fluid Compatibility Silicone Oil Type 200.10
Tank Opening Diameter 4.4 in
Thermocouple Temperature Celsius - Minimum -25 Degrees C
Freight Class Code 18
Product Powered by Fossil Fuel N
Accuracy +/- 0.1 Degrees C
Fluid Volume 2.5 L
Typical Uniformity 0.02 Degrees C
Tank Depth 6.1 in
Includes NIST-Traceable Certificate Yes
Thermocouple Temperature Range -13 Degrees F to 284 Degrees F ; -25 Degrees C to 250 Degrees C
Manufacturer Part Number 7109A-P-156
Thermocouple Temperature Fahrenheit - Maximum 284 Degrees F
Display Resolution 0.01 Degrees, 0.001 Degrees
RTD Temperature Range -13 Degrees F to 284 Degrees F ; -25 Degrees C to 140 Degrees C
Storage Protection Code A
Mfr. Model # 7109A-P-156
Description

Thermometer Calibrator, 24VDC, 15" H

Catalog Page 572