Thermometer Calibrator: 95°F to 482°F /-25°C to 140°C, 95°F to 482°F /35°C to 250°C, +/- 0.1°C
In Stock
$14,182.00
/each
Earn 14182 points with this purchase
Request quantity discount pricing
You're Viewing
FLUKE Thermometer Calibrator: 95°F to 482°F /-25°C...
Item 54DD52
$14,182.00
Customers Also Viewed
No related products found.
Product Details
| Catalog Page | 572 |
| Brand | FLUKE |
| RTD Temperature Fahrenheit - Maximum | 482 Degrees F |
| Includes NIST-Traceable Certificate | Yes |
| Thermocouple Temperature Range | 95 Degrees F to 482 Degrees F ; 35 Degrees C to 250 Degrees C |
| Thermocouple Temperature Celsius - Minimum | 35 Degrees C |
| Display Qty | 1 |
| RTD Temperature Celsius - Minimum | -25 Degrees C |
| Typical Settling Time | 15 min |
| Is this a Hazardous Material Product? | N |
| Voltage | 24 V DC |
| RTD Temperature Range | 95 Degrees F to 482 Degrees F ; -25 Degrees C to 140 Degrees C |
| Calibrator Weight | 35 lb |
| Overall Width | 9.5 in |
| Ozone Depleting Substance | N |
| EnvironmentallyPreferable_Indicator | N |
| RTD Temperature Fahrenheit - Minimum | 95 Degrees F |
| Manufacturer Part Number | 6109A-156 |
| Power Source | Loop Power |
| Storage Protection Code | A |
| Thermocouple Temperature Celsius - Maximum | 250 Degrees C |
| Overall Height | 15 in |
| Interface | RS-232 |
| Product Powered by Fossil Fuel | N |
| California Prop 65 Reproductive Harm | N |
| Overall Depth | 15.4 in |
| RTD Temperature Celsius - Maximum | 140 Degrees C |
| Thermocouple Temperature Fahrenheit - Maximum | 482 Degrees F |
| Display Resolution | 0.01 Degrees, 0.001 Degrees |
| Fluid Volume | 2.5 L |
| Safety Data Sheet (SDS) Applicable? | N |
| Tank Opening Diameter | 4.4 in |
| Repeatability | 0.04 Degrees C |
| RoHS - Restricted Use of Hazardous Substances Directive (RoHS) | N |
| Accuracy | +/- 0.1 Degrees C |
| Stability | 0.015 Degrees C |
| Common Fluid Compatibility | Silicone Oil Type 200.50 |
| Thermocouple Temperature Fahrenheit - Minimum | 95 Degrees F |
| California Prop 65 Cancer | N |
| Typical Uniformity | 0.03 Degrees C up to 200 Degrees C, 0.04 Degrees C above 200 Degrees C |
| Freight Class Code | 18 |
| Typical Cooling Time | 55 min (100 Degrees to 35 Degrees C), 35 min (250 Degrees to 100 Degrees C) |
| Tank Depth | 6.1 in |
| Typical Heating Time | 45 min (100 Degrees to 250 Degrees C), 25 min (35 Degrees to 100 Degrees C) |
| Standards | FDA, ISO |
| Should Sales be Restricted by Region? | N |
| Display Sell UOM | EA |
| Mfr. Model # | 6109A-156 |
Description
Thermometer Calibrator, 24VDC, 15" H