657-600-0865 | contact@KDdepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Dry Well Calibrator: 14°F to 252°F /-10°C to 122°C, 14°F to 252°F /-10°C to 122°C
Dry Well Calibrator: 14°F to 252°F /-10°C to 122°C, 14°F to 252°F /-10°C to 122°C

Product Image

Dry Well Calibrator: 14°F to 252°F /-10°C to 122°C, 14°F to 252°F /-10°C to 122°C

Item 4LHA2 Mfr. Model # 9102S-156
In Stock
$6,832.00 /each
Earn 6832 points with this purchase
Request quantity discount pricing
You're Viewing
Dry Well Calibrator: 14°F to 252°F /-10°C to 122°C, 14°F to 252°F /-10°C to 122°C
FLUKE Dry Well Calibrator: 14°F to 252°F /-10°C to...
Item 4LHA2
$6,832.00
Customers Also Viewed

No related products found.

Product Details

Brand FLUKE
Freight Class Code 43
Overall Depth 6.91 in
Should Sales be Restricted by Region? N
Includes NIST-Traceable Certificate Yes
Calibrator Weight 4 lb
Thermocouple Temperature Celsius - Maximum 122 Degrees C
Number of Inserts Included 1
Calibration Certificate Type NIST Traceable
California Prop 65 Cancer N
Display Qty 1
For RTD Type 3-Wire, 4-Wire, 2-Wire, Pt 100 (385)
Typical Heating Time 10 min (Ambient to 100 Degrees C)
RTD Temperature Range 14 Degrees F to 252 Degrees F ; -10 Degrees C to 122 Degrees C
Storage Protection Code A
Thermocouple Temperature Celsius - Minimum -10 Degrees C
Calibrator Accuracy +/-0.25 Degrees C
Process Connections Included RTD, Thermocouple
Sensor Technology RTD
RTD Temperature Celsius - Maximum 122 Degrees C
For Stem Diameter 0.3125 in, 0.375 in, 0.125 in, 0.25 in, 0.4375 in, 0.15625 in, 0.0625 in, 0.1875 in
Typical Uniformity +/-0.2 Degrees C
RTD Temperature Fahrenheit - Maximum 252 Degrees F
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Ozone Depleting Substance N
Product Powered by Fossil Fuel N
Thermocouple Temperature Range 14 Degrees F to 252 Degrees F ; -10 Degrees C to 122 Degrees C
Display Resolution 0.1 Degrees F
RTD Temperature Fahrenheit - Minimum 14 Degrees F
Stabilization Time 5 min
Display Sell UOM EA
Set Point Style Adjustable
Stability +/- 0.05 Degrees C
Safety Data Sheet (SDS) Applicable? N
California Prop 65 Reproductive Harm N
Thermocouple Temperature Fahrenheit - Minimum 14 Degrees F
Power Source Plug-In
For Thermocouple Type Type E, Type J, Type K, Type T
Temperature Set Points -30 Degrees C, 650 Degrees C
Voltage 12V DC, 94 to 234V AC
RTD Temperature Celsius - Minimum -10 Degrees C
Overall Width 5.5 in
Overall Height 3.91 in
Manufacturer Part Number 9102S-156
Is this a Hazardous Material Product? N
Well Depth 4 in
Interface RS-232
Number of Insert Holes 5
EnvironmentallyPreferable_Indicator N
Typical Cooling Time 10 min (Ambient to 0 Degrees C)
Single Well/Dual Well Single Well
Thermocouple Temperature Fahrenheit - Maximum 252 Degrees F
Interchangeable Insert Yes
Mfr. Model # 9102S-156
Description

Dry Well Calibrator, 14-252 Degrees F

Catalog Page 0