Dry Well Calibrator: 14°F to 252°F /-10°C to 122°C, 14°F to 252°F /-10°C to 122°C
In Stock
$6,832.00
/each
Earn 6832 points with this purchase
Request quantity discount pricing
You're Viewing
FLUKE Dry Well Calibrator: 14°F to 252°F /-10°C to...
Item 4LHA2
$6,832.00
Customers Also Viewed
No related products found.
Product Details
| Brand | FLUKE |
| Freight Class Code | 43 |
| Overall Depth | 6.91 in |
| Should Sales be Restricted by Region? | N |
| Includes NIST-Traceable Certificate | Yes |
| Calibrator Weight | 4 lb |
| Thermocouple Temperature Celsius - Maximum | 122 Degrees C |
| Number of Inserts Included | 1 |
| Calibration Certificate Type | NIST Traceable |
| California Prop 65 Cancer | N |
| Display Qty | 1 |
| For RTD Type | 3-Wire, 4-Wire, 2-Wire, Pt 100 (385) |
| Typical Heating Time | 10 min (Ambient to 100 Degrees C) |
| RTD Temperature Range | 14 Degrees F to 252 Degrees F ; -10 Degrees C to 122 Degrees C |
| Storage Protection Code | A |
| Thermocouple Temperature Celsius - Minimum | -10 Degrees C |
| Calibrator Accuracy | +/-0.25 Degrees C |
| Process Connections Included | RTD, Thermocouple |
| Sensor Technology | RTD |
| RTD Temperature Celsius - Maximum | 122 Degrees C |
| For Stem Diameter | 0.3125 in, 0.375 in, 0.125 in, 0.25 in, 0.4375 in, 0.15625 in, 0.0625 in, 0.1875 in |
| Typical Uniformity | +/-0.2 Degrees C |
| RTD Temperature Fahrenheit - Maximum | 252 Degrees F |
| RoHS - Restricted Use of Hazardous Substances Directive (RoHS) | N |
| Ozone Depleting Substance | N |
| Product Powered by Fossil Fuel | N |
| Thermocouple Temperature Range | 14 Degrees F to 252 Degrees F ; -10 Degrees C to 122 Degrees C |
| Display Resolution | 0.1 Degrees F |
| RTD Temperature Fahrenheit - Minimum | 14 Degrees F |
| Stabilization Time | 5 min |
| Display Sell UOM | EA |
| Set Point Style | Adjustable |
| Stability | +/- 0.05 Degrees C |
| Safety Data Sheet (SDS) Applicable? | N |
| California Prop 65 Reproductive Harm | N |
| Thermocouple Temperature Fahrenheit - Minimum | 14 Degrees F |
| Power Source | Plug-In |
| For Thermocouple Type | Type E, Type J, Type K, Type T |
| Temperature Set Points | -30 Degrees C, 650 Degrees C |
| Voltage | 12V DC, 94 to 234V AC |
| RTD Temperature Celsius - Minimum | -10 Degrees C |
| Overall Width | 5.5 in |
| Overall Height | 3.91 in |
| Manufacturer Part Number | 9102S-156 |
| Is this a Hazardous Material Product? | N |
| Well Depth | 4 in |
| Interface | RS-232 |
| Number of Insert Holes | 5 |
| EnvironmentallyPreferable_Indicator | N |
| Typical Cooling Time | 10 min (Ambient to 0 Degrees C) |
| Single Well/Dual Well | Single Well |
| Thermocouple Temperature Fahrenheit - Maximum | 252 Degrees F |
| Interchangeable Insert | Yes |
| Mfr. Model # | 9102S-156 |
Description