Dry Well Calibrator: 95°F to 707°F /35°C to 375°C, 95°F to 707°F /35°C to 375°C
Dry Well Calibrator: 95°F to 707°F /35°C to 375°C, 95°F to 707°F /35°C to 375°C

Product Image

Dry Well Calibrator: 95°F to 707°F /35°C to 375°C, 95°F to 707°F /35°C to 375°C

Item 4LGZ9 Mfr. Model # 9100S-A-156
In Stock
$4,284.00 /each
Earn 4284 points with this purchase
Request quantity discount pricing
You're Viewing
Dry Well Calibrator: 95°F to 707°F /35°C to 375°C, 95°F to 707°F /35°C to 375°C
FLUKE Dry Well Calibrator: 95°F to 707°F /35°C to 3...
Item 4LGZ9
$4,284.00
Customers Also Viewed

No related products found.

Product Details

Brand FLUKE
California Prop 65 Cancer N
Overall Width 4.91 in
Thermocouple Temperature Celsius - Minimum 35 Degrees C
RTD Temperature Celsius - Minimum 35 Degrees C
Safety Data Sheet (SDS) Applicable? N
Display Qty 1
Temperature Set Points -10 Degrees C, 375 Degrees C
Power Source Plug-In
Product Powered by Fossil Fuel N
Storage Protection Code A
Is this a Hazardous Material Product? N
Sensor Technology RTD
RTD Temperature Celsius - Maximum 375 Degrees C
RTD Temperature Fahrenheit - Minimum 95 Degrees F
Insert Type Included A
Calibrator Accuracy +/-0.5 Degrees C at 375 Degrees C, +/-0.25 Degrees C at 50 Degrees C, +/-0.25 Degrees C at 100 Degrees C
RTD Temperature Fahrenheit - Maximum 707 Degrees F
Stability +/-0.07 Degrees C at 50 Degrees C, +/-0.1 Degrees C at 100 Degrees C, +/-0.3 Degrees C at 375 Degrees C
Calibration Certificate Type NIST Traceable
Freight Class Code 43
Display Resolution 0.1 Degrees F
For RTD Type 3-Wire, 4-Wire, 2-Wire
Manufacturer Part Number 9100S-A-156
Should Sales be Restricted by Region? N
Calibrator Weight 2 lb
Interface RS-232
Set Point Style Adjustable
Typical Cooling Time 14 min (375 Degrees to 100 Degrees C)
Interchangeable Insert Yes
Stabilization Time 5 min
Well Depth 4 in
For Thermocouple Type Type E, Type J, Type K, Type T
Thermocouple Temperature Range 95 Degrees F to 707 Degrees F ; 35 Degrees C to 375 Degrees C
Overall Depth 6.11 in
California Prop 65 Reproductive Harm N
Insert Hole Diameter 4-4/5 mm, 6-2/5 mm
Typical Heating Time 9.5 min (35 Degrees to 375 Degrees C)
Voltage 115V AC, 230V AC
Display Sell UOM EA
Includes NIST-Traceable Certificate Yes
Thermocouple Temperature Fahrenheit - Maximum 707 Degrees F
Process Connections Included RTD, Thermocouple
RTD Temperature Range 95 Degrees F to 707 Degrees F ; 35 Degrees C to 375 Degrees C
Typical Uniformity +/-0.2 Degrees C
EnvironmentallyPreferable_Indicator N
Overall Height 2.25 in
Ozone Depleting Substance N
Single Well/Dual Well Single Well
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Number of Insert Holes 5
For Stem Diameter 0.125 in, 0.25 in, 0.15625 in, 0.0625 in, 0.1875 in
Thermocouple Temperature Fahrenheit - Minimum 95 Degrees F
Number of Inserts Included 1
Thermocouple Temperature Celsius - Maximum 375 Degrees C
Mfr. Model # 9100S-A-156
Description

Dry Well Calibrator, 1/16-1/4 In Hole

Catalog Page 0