657-600-0865 | contact@KDdepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Drywall Temperature Calibrator: 95°F to 707°F /35°C to 375°C, 95°F to 707°F /35°C to 375°C
Drywall Temperature Calibrator: 95°F to 707°F /35°C to 375°C, 95°F to 707°F /35°C to 375°C

Product Image

Drywall Temperature Calibrator: 95°F to 707°F /35°C to 375°C, 95°F to 707°F /35°C to 375°C

Item KD-0408965 Mfr. Model # 9100S-A-156
In Stock
$5,101.00 /each
Earn 5101 points with this purchase
Request quantity discount pricing
You're Viewing
Drywall Temperature Calibrator: 95°F to 707°F /35°C to 375°C, 95°F to 707°F /35°C to 375°C
FLUKE Drywall Temperature Calibrator: 95°F to 707°F...
Item KD-0408965
$5,101.00
Customers Also Viewed

No related products found.

Product Details

Brand FLUKE
Thermocouple Temperature Fahrenheit - Maximum 707 Degrees F
Contains California Prop 65 Reproductive Toxicant N
For RTD Type 3-Wire, 4-Wire, 2-Wire
Stabilization Time 5 min
Thermocouple Temperature Fahrenheit - Minimum 95 Degrees F
Calibrator Weight 2 lb
Well Depth 4 in
Manufacturer Part Number 9100S-A-156
Includes NIST-Traceable Certificate Yes
Number of Insert Holes 5
Display Resolution 0.1 Degrees F
Thermocouple Temperature Range 95 Degrees F to 707 Degrees F ; 35 Degrees C to 375 Degrees C
Overall Depth 6.11 in
Insert Type Included A
Power Source Plug-In
Display Sell UOM EA
Insert Hole Diameter 4-4/5 mm, 6-2/5 mm
Sensor Technology RTD
Calibration Certificate Type NIST Traceable
Process Connections Included RTD, Thermocouple
RTD Temperature Celsius - Maximum 375 Degrees C
For Stem Diameter 0.125 in, 0.25 in, 0.15625 in, 0.0625 in, 0.1875 in
Overall Width 4.91 in
Contains California Prop 65 Carcinogen N
Thermocouple Temperature Celsius - Maximum 375 Degrees C
Number of Inserts Included 1
Voltage 115V AC, 230V AC
Interchangeable Insert Yes
Interface RS-232
Stability +/-0.07 Degrees C at 50 Degrees C, +/-0.1 Degrees C at 100 Degrees C, +/-0.3 Degrees C at 375 Degrees C
For Thermocouple Type Type E, Type J, Type K, Type T
Display Qty 1
RTD Temperature Celsius - Minimum 35 Degrees C
RTD Temperature Fahrenheit - Minimum 95 Degrees F
Set Point Style Adjustable
RTD Temperature Range 95 Degrees F to 707 Degrees F ; 35 Degrees C to 375 Degrees C
Calibrator Accuracy +/-0.5 Degrees C at 375 Degrees C, +/-0.25 Degrees C at 50 Degrees C, +/-0.25 Degrees C at 100 Degrees C
Single Well/Dual Well Single Well
Thermocouple Temperature Celsius - Minimum 35 Degrees C
Temperature Set Points -10 Degrees C, 375 Degrees C
Overall Height 2.25 in
Typical Cooling Time 14 min (375 Degrees to 100 Degrees C)
Typical Uniformity +/-0.2 Degrees C
Typical Heating Time 9.5 min (35 Degrees to 375 Degrees C)
RTD Temperature Fahrenheit - Maximum 707 Degrees F
Mfr. Model # 9100S-A-156
Description

Drywal Temp Calib, Plug-In, 95, 707 F

Catalog Page 0