Reset Volume Controller: 2000 Series, Reverse Acting, Normally Closed, 3 to 8 psi
Reset Volume Controller: 2000 Series, Reverse Acting, Normally Closed, 3 to 8 psi

Product Image

Reset Volume Controller: 2000 Series, Reverse Acting, Normally Closed, 3 to 8 psi

Item KD-1140369 Mfr. Model # CSC-2008
In Stock
$228.50 /each
Earn 228 points with this purchase
Request quantity discount pricing
You're Viewing
Reset Volume Controller: 2000 Series, Reverse Acting, Normally Closed, 3 to 8 psi
KMC CONTROLS Reset Volume Controller: 2000 Series, Reverse...
Item KD-1140369
$228.50
Customers Also Viewed

No related products found.

Product Details

Catalog Page 2913
Brand KMC CONTROLS
Freight Class Code 18
Reset Start Point Minimum Setting 3 psi
Air Inlet Size 1/4 in
Includes Mounting Bracket
Output Pressure Capability 0 to Supply Pressure
Damper Action Normally Closed
Maximum Air Pressure 30 psi
Should Sales be Restricted by Region? N
Contains California Prop 65 Reproductive Toxicant N
Special Permits for Any Mode of Transportation 0
Maximum Signal Pressure 6 in wc
Thermostat Required for Cooling Reverse Acting
Is this a Hazardous Material Product? N
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Air Inlet Type Push-On
Housing Color Gray
Manufacturer Part Number CSC-2008
Product Powered by Fossil Fuel N
Mounting Orientation Vertical, Horizontal
Standards RoHS Compliant
Set Point Range 0 to 1 in wc to Min + 1 in wc
Minimum Setpoint Range Minimum 0 to 1 in wc
Storage Protection Code A
Housing Material ABS
Series 2000
Application Variable Air Volume
Minimum Operating Temperature 40 Degrees F
Minimum Air Pressure 15 psi
Air Consumption 11.5 scim
Output Sensitivity 5 psi / 0.02 in wc
Air Pressure Range 15 psi to 30 psi
Controller Action Reverse Acting
Mounting Hole Diameter 3/16 in
Ozone Depleting Substance N
Operating Pressure 15 to 30 psi
Thermostat Required: Heating - Cooling Direct Acting - Reverse Acting
Is the item Limited Quantity for Transportation? N
Reset Start Point Range 3 to 8 psi
Maximum Operating Temperature 120 Degrees F
Reset Start Point 3 psi to 8 psi
Reset Start Point Maximum Setting 8 psi
Maximum Setpoint Range Min + 1 in wc
Thermostat Required for Heating Direct Acting
Safety Data Sheet (SDS) Applicable? N
Contains California Prop 65 Carcinogen N
Weight 0.47 lb
Reset Start Point Factory Setting 3 psi
Mfr. Model # CSC-2008
Description

Reset Volume Controller, 15 to 30 psi

Catalog Page 2913