657-600-0865 | contact@KDdepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Reset Volume Controller: 2000 Series, Direct Acting, Normally Open, 8 psi to 13 psi Rest Start Point
Reset Volume Controller: 2000 Series, Direct Acting, Normally Open, 8 psi to 13 psi Rest Start Point

Product Image

Reset Volume Controller: 2000 Series, Direct Acting, Normally Open, 8 psi to 13 psi Rest Start Point

Item 4DDZ2 Mfr. Model # CSC-2001
In Stock
$236.75 /each
Earn 236 points with this purchase
Request quantity discount pricing
You're Viewing
Reset Volume Controller: 2000 Series, Direct Acting, Normally Open, 8 psi to 13 psi Rest Start Point
KMC CONTROLS Reset Volume Controller: 2000 Series, Direct...
Item 4DDZ2
$236.75
Customers Also Viewed

No related products found.

Product Details

Catalog Page 2913
Brand KMC CONTROLS
Controller Action Direct Acting
Standards RoHS Compliant
Air Inlet Type Push-On
Should Sales be Restricted by Region? N
Minimum Setpoint Range Minimum 0 to 1 in wc
Safety Data Sheet (SDS) Applicable? N
Air Consumption 14.4 scim
Maximum Operating Temperature 120 Degrees F
Mounting Hole Diameter 3/16 in
Manufacturer Part Number CSC-2001
Air Pressure Range 15 psi to 30 psi
Reset Start Point Factory Setting 8 psi
Housing Color Beige
Minimum Air Pressure 15 psi
Mounting Orientation Horizontal with Dial Up
Reset Start Point Maximum Setting 13 psi
Minimum Operating Temperature 40 Degrees F
Application Variable Air Volume
Output Pressure Capability 0 to Supply Pressure
Is the item Limited Quantity for Transportation? N
Thermostat Required for Heating Reverse Acting
Maximum Signal Pressure 6 in wc
Series 2000
Special Permits for Any Mode of Transportation 0
Housing Material ABS
Storage Protection Code A
Maximum Setpoint Range Min + 1 in wc
Reset Start Point Minimum Setting 8 psi
Freight Class Code 18
Ozone Depleting Substance N
Set Point Range 0 to 1 in wc to Min + 1 in wc
Damper Action Normally Open
Maximum Air Pressure 30 psi
Reset Start Point 8 psi to 13 psi
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Thermostat Required: Heating - Cooling Reverse Acting - Direct Acting
Weight 0.47 lb
Air Inlet Size 1/4 in
California Prop 65 Reproductive Harm N
Operating Pressure 15 to 30 psi
Reset Start Point Range 8 to 13 psi
California Prop 65 Cancer N
Includes Mounting Bracket
Product Powered by Fossil Fuel N
Thermostat Required for Cooling Direct Acting
Output Sensitivity 5 psi / 0.02 in wc
Is this a Hazardous Material Product? N
Mfr. Model # CSC-2001
Description

Reset Volume Controller, 15 to 30 psi

Catalog Page 2913