| Catalog Page | 518 |
| Brand | EXTECH |
| Is this a Hazardous Material Product? | N |
| Overall Width | 3 in |
| Frequency Measurement Resolution | 0.01 Hz |
| Batteries Included | Yes |
| Capacitance Measurement Accuracy | +/-10.00% |
| Ozone Depleting Substance | N |
| Resistance Measurement Resolution | 0.1 ohm |
| Maximum DC Voltage Measurement | 1,000 V |
| Maximum Operating Temperature | 122 Degrees F |
| Digital/Analog | Digital |
| Frequency Measurement Accuracy | +/-0.10% |
| Jaw Style | Clamp |
| Maximum Resistance Measurement | 60 megaohm |
| Minimum DC Voltage Measurement | 600 mV |
| Standards | CE, cULus |
| Resistance Measurement Accuracy | +/-1.50% |
| Parameters Measured | AC Current, DC Voltage, Inrush Current, Continuity, Diode, DC Current, AC Voltage, Frequency, Temperature, Capacitance, Resistance |
| Jaw Opening | 1.18 in |
| Includes | Test Leads, (3) Batteries, Type K Bead Wire Temperature Probe |
| Non-Contact Voltage Detector | Yes |
| Overall Height | 1.6 in |
| Inrush | Yes |
| Display Sell UOM | EA |
| Auto Ranging | Yes |
| Basic AC Voltage Accuracy | +/-1.50% |
| Features_Combined | Data Logging: Yes ; Intrinsically Safe: No ; Thermal Imaging: No ; DC Voltage, Data Logging: Yes ; Intrinsically Safe: No ; Thermal Imaging: No ; Continuity, Data Logging: Yes ; Intrinsically Safe: No ; Thermal Imaging: No ; Frequency, Data Logging: Yes ; Intrinsically Safe: No ; Thermal Imaging: No ; AC Current, Data Logging: Yes ; Intrinsically Safe: No ; Thermal Imaging: No ; Inrush Current, Data Logging: Yes ; Intrinsically Safe: No ; Thermal Imaging: No ; Resistance, Data Logging: Yes ; Intrinsically Safe: No ; Thermal Imaging: No ; Temperature, Data Logging: Yes ; Intrinsically Safe: No ; Thermal Imaging: No ; Diode, Data Logging: Yes ; Intrinsically Safe: No ; Thermal Imaging: No ; Capacitance, Data Logging: Yes ; Intrinsically Safe: No ; Thermal Imaging: No ; DC Current, Data Logging: Yes ; Intrinsically Safe: No ; Thermal Imaging: No ; AC Voltage |
| Manufacturer Part Number | EX655 |
| DC Current Range | 600 uA to 600 A |
| Safety Data Sheet (SDS) Applicable? | N |
| AC Current Measurement Resolution | 0.1 uA, 0.01 A |
| DC Current Measurement Resolution | 0.1 uA |
| Peak Hold | No |
| Capacitance Measurement Resolution | 0.01 nF |
| Should Sales be Restricted by Region? | N |
| Data Logging | Yes |
| RoHS - Restricted Use of Hazardous Substances Directive (RoHS) | N |
| Maximum Storage Temperature | 140 Degrees F |
| Basic DC Voltage Accuracy | +/-1.00% |
| Battery Size | AAA |
| Intrinsically Safe | No |
| AC Voltage Measurement Resolution | 1 mV |
| Battery Access | Yes |
| Maximum AC Voltage Measurement | 750 V |
| Minimum Storage Temperature | -4 Degrees F |
| Minimum AC Voltage Measurement | 6 V |
| Current Units | uA, A |
| Temperature Types Measured | Temperature Degrees F, Temperature Degrees C |
| Basic DC Current Accuracy | +/-2.50% |
| AC Current Range | 600 uA to 600 A |
| Maximum Conductor Size | 350MCM |
| California Prop 65 Cancer | N |
| Thermometer Type | Type K Thermocouple |
| Features_Subhead | Data Logging |
| Jaw Detachability | Fixed |
| Freight Class Code | 43 |
| Storage Protection Code | A |
| DC Voltage Range | 600 mV to 1,000 V |
| Maximum Frequency Measurement | 1 MHz |
| Basic AC Current Accuracy | +/-2.50% |
| AC Response Calculation | TRMS |
| Minimum Capacitance Measurement | 60 nF |
| Minimum DC Current Measurement | 600 uA |
| Maximum DC Current Measurement | 600 A |
| Instrument Counts | 6000 |
| Product Powered by Fossil Fuel | N |
| Bluetooth | No |
| Display Type | Backlit LCD |
| Removable Screen | No |
| Display Qty | 1 |
| Maximum AC Current Measurement | 600 A |
| Calibration Certificate Included | No Certification Included, Not Included |
| Minimum Frequency Measurement | 10 Hz |
| Includes Auto Sensing | No Auto Sensing Included |
| Minimum Operating Temperature | 32 Degrees F |
| Audible Continuity | Yes |
| Current Leakage Testing | No |
| Voltage Units | V, mV |
| Data Hold | Yes |
| Thermal Imaging | No |
| Diode Test | Yes |
| AC Voltage Range | 6 V to 750 V |
| Features | 1.18" (30mm) jaw size accomodates conductors up to 350MCM, Low Impedance (LoZ) prevents false reading caused by ghost voltages, Built-in non-contact voltage detector (NCV) with LED indicator, DC Zero mode, Data Hold, Min/Max, Relative function, Auto Power Off, Low Pass Filter (LPF) for accurate measurements of variable frequency drive signals, 6000 count backlit LCD display with bargraph, Inrush mode captures current surges during motor startup, Built-in LED flashlight for working in dimly-lit areas |
| Bar Graph Included | Yes |
| California Prop 65 Reproductive Harm | N |
| Minimum Resistance Measurement | 600 ohm |
| CAT Safety Rating | CAT II 1000V, CAT III 600V |
| Auto Power Off | Yes |
| Manufacturers Warranty Length | 3 yr |
| Memory | Min/Max |
| DC Voltage Measurement Resolution | 0.1 mV |
| Maximum Capacitance Measurement | 60 mF |
| Minimum AC Current Measurement | 600 uA |
| Mfr. Model # | EX655 |
Description
DigitalClampMeter, TRMS, 600A, 750VAC