657-600-0865 | contact@KDdepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Drywell: 32°F to 2696°F /-25°C to 1480°C, 77°F to 1220°F /-25°C to 660°C, Adj Set Point
Drywell: 32°F to 2696°F /-25°C to 1480°C, 77°F to 1220°F /-25°C to 660°C, Adj Set Point

Product Image

Drywell: 32°F to 2696°F /-25°C to 1480°C, 77°F to 1220°F /-25°C to 660°C, Adj Set Point

Item 33W992 Mfr. Model # 9144-E-156
In Stock
$9,508.00 /each
Earn 9508 points with this purchase
Request quantity discount pricing
You're Viewing
Drywell: 32°F to 2696°F /-25°C to 1480°C, 77°F to 1220°F /-25°C to 660°C, Adj Set Point
FLUKE Drywell: 32°F to 2696°F /-25°C to 1480°C, 77°...
Item 33W992
$9,508.00
Customers Also Viewed

No related products found.

Product Details

Catalog Page 572
Brand FLUKE
Freight Class Code 43
Typical Uniformity +/-0.05 Degrees C at 50 Degrees C, +/-0.35 Degrees C at 420 Degrees C, +/-0.5 Degrees C at 660 Degrees C, +/-0.02 Degrees C at 50 Degrees C, +/-0.05 Degrees C at 420 Degrees C, +/-0.10 Degrees C at 660 Degrees C
EnvironmentallyPreferable_Indicator N
Single Well/Dual Well Single Well
Should Sales be Restricted by Region? N
Insert Type Included E
For RTD Type 3-Wire, 4-Wire, 2-Wire, Pt 100 (385)
Stabilization Time 10 min
Typical Heating Time 15 min (50 Degrees to 660 Degrees C)
For Thermocouple Type Type B, Type E, Type J, Type K, Type R, Type S, Type T
For Stem Diameter 10 mm, 6 mm, 1/4 in, 8 mm, 4 mm
Thermocouple Temperature Celsius - Minimum 0 Degrees C
Display Qty 1
California Prop 65 Cancer N
Includes NIST-Traceable Certificate No
Calibrator Accuracy +/-0.35 Degrees C at 50 Degrees C, +/-0.35 Degrees C at 420 Degrees C, +/-0.5 Degrees C at 660 Degrees C
RTD Temperature Celsius - Minimum -25 Degrees C
Overall Depth 11.61 in
RTD Temperature Celsius - Maximum 660 Degrees C
Calibrator Weight 17 lb
Overall Width 7.31 in
California Prop 65 Reproductive Harm N
Thermocouple Temperature Range 32 Degrees F to 2696 Degrees F ; -25 Degrees C to 1480 Degrees C
Display Sell UOM EA
RTD Temperature Range 77 Degrees F to 1220 Degrees F ; -25 Degrees C to 660 Degrees C
Power Source Plug-In
Thermocouple Temperature Celsius - Maximum 1480 Degrees C
Display Resolution 0.01 Degrees F
Typical Cooling Time 25 min (660 Degrees to 100 Degrees C), 35 min (660 Degrees to 50 Degrees C)
RTD Temperature Fahrenheit - Minimum 77 Degrees F
Number of Insert Holes 5
Voltage 100 to 115V, 230V
Number of Inserts Included 1
Manufacturer Part Number 9144-E-156
RTD Temperature Fahrenheit - Maximum 1220 Degrees F
Storage Protection Code A
Set Point Style Adjustable
Product Powered by Fossil Fuel N
Ozone Depleting Substance N
Safety Data Sheet (SDS) Applicable? N
Thermocouple Temperature Fahrenheit - Minimum 32 Degrees F
Is this a Hazardous Material Product? N
Interface RS-232
Process Connections Included RTD, Thermocouple, Transmitter
Well Depth 5.91 in
Temperature Set Points 50 Degrees C, 660 Degrees C
Insert Hole Diameter 6 mm, 4 mm, 6-7/20 mm, 10 mm, 8 mm
Thermocouple Temperature Fahrenheit - Maximum 2696 Degrees F
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Sensor Technology RTD
Stability +/-0.04 Degrees C at 420 Degrees C, +/-0.03 Degrees C at 50 Degrees C, +/-0.05 Degrees C at 660 Degrees C
Standards NVLAP Accredited
Interchangeable Insert Yes
Overall Height 11.41 in
Mfr. Model # 9144-E-156
Description

Drywell, Temperature

Catalog Page 572