657-600-0865 | contact@KDdepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Drywell: 32°F to 2696°F /-25°C to 1480°C, 77°F to 1220°F /-25°C to 660°C, Adj Set Point
Drywell: 32°F to 2696°F /-25°C to 1480°C, 77°F to 1220°F /-25°C to 660°C, Adj Set Point

Product Image

Drywell: 32°F to 2696°F /-25°C to 1480°C, 77°F to 1220°F /-25°C to 660°C, Adj Set Point

Item KD-0408873 Mfr. Model # 9144-D-156
In Stock
$10,350.00 /each
Earn 10350 points with this purchase
Request quantity discount pricing
You're Viewing
Drywell: 32°F to 2696°F /-25°C to 1480°C, 77°F to 1220°F /-25°C to 660°C, Adj Set Point
FLUKE Drywell: 32°F to 2696°F /-25°C to 1480°C, 77°...
Item KD-0408873
$10,350.00
Customers Also Viewed

No related products found.

Product Details

Catalog Page 572
Brand FLUKE
For RTD Type 3-Wire, 4-Wire, 2-Wire, Pt 100 (385)
Thermocouple Temperature Celsius - Maximum 1480 Degrees C
Sensor Technology RTD
Calibrator Weight 17 lb
Stabilization Time 10 min
Insert Hole Diameter 6 mm, 3 mm, 4 mm
Thermocouple Temperature Range 32 Degrees F to 2696 Degrees F ; -25 Degrees C to 1480 Degrees C
For Thermocouple Type Type B, Type E, Type J, Type K, Type R, Type S, Type T
Overall Height 11.41 in
Set Point Style Adjustable
Single Well/Dual Well Single Well
Number of Insert Holes 6
Standards NVLAP Accredited
Includes NIST-Traceable Certificate No
Display Sell UOM EA
Display Qty 1
Insert Type Included D
RTD Temperature Celsius - Maximum 660 Degrees C
Typical Cooling Time 25 min (660 Degrees to 100 Degrees C), 35 min (660 Degrees to 50 Degrees C)
Overall Depth 11.61 in
Power Source Plug-In
Process Connections Included RTD, Thermocouple, Transmitter
Typical Uniformity +/-0.05 Degrees C at 50 Degrees C, +/-0.35 Degrees C at 420 Degrees C, +/-0.5 Degrees C at 660 Degrees C, +/-0.02 Degrees C at 50 Degrees C, +/-0.05 Degrees C at 420 Degrees C, +/-0.10 Degrees C at 660 Degrees C
Thermocouple Temperature Fahrenheit - Minimum 32 Degrees F
Contains California Prop 65 Reproductive Toxicant N
Overall Width 7.31 in
Typical Heating Time 15 min (50 Degrees to 660 Degrees C)
Display Resolution 0.01 Degrees F
Interchangeable Insert Yes
RTD Temperature Fahrenheit - Maximum 1220 Degrees F
Thermocouple Temperature Celsius - Minimum 0 Degrees C
RTD Temperature Range 77 Degrees F to 1220 Degrees F ; -25 Degrees C to 660 Degrees C
Calibrator Accuracy +/-0.35 Degrees C at 50 Degrees C, +/-0.35 Degrees C at 420 Degrees C, +/-0.5 Degrees C at 660 Degrees C
Well Depth 5.91 in
RTD Temperature Celsius - Minimum -25 Degrees C
Voltage 100 to 115V, 230V
Interface RS-232
For Stem Diameter (2) 4 mm, (2) 3 mm, (2) 6 mm
Thermocouple Temperature Fahrenheit - Maximum 2696 Degrees F
Temperature Set Points 50 Degrees C, 660 Degrees C
Contains California Prop 65 Carcinogen N
Stability +/-0.04 Degrees C at 420 Degrees C, +/-0.03 Degrees C at 50 Degrees C, +/-0.05 Degrees C at 660 Degrees C
Manufacturer Part Number 9144-D-156
Number of Inserts Included 1
RTD Temperature Fahrenheit - Minimum 77 Degrees F
Mfr. Model # 9144-D-156
Description

Drywal Temp Calib, Plug-In, 77, 1220 F

Catalog Page 572