Drywell: 32°F to 2696°F /-25°C to 1480°C, 77°F to 1220°F /-25°C to 660°C, Adj Set Point
Drywell: 32°F to 2696°F /-25°C to 1480°C, 77°F to 1220°F /-25°C to 660°C, Adj Set Point

Product Image

Drywell: 32°F to 2696°F /-25°C to 1480°C, 77°F to 1220°F /-25°C to 660°C, Adj Set Point

Item KD-0408885 Mfr. Model # 9144-A-P-156
In Stock
$13,394.00 /each
Earn 13394 points with this purchase
Request quantity discount pricing
You're Viewing
Drywell: 32°F to 2696°F /-25°C to 1480°C, 77°F to 1220°F /-25°C to 660°C, Adj Set Point
FLUKE Drywell: 32°F to 2696°F /-25°C to 1480°C, 77°...
Item KD-0408885
$13,394.00
Customers Also Viewed

No related products found.

Product Details

Catalog Page 572
Brand FLUKE
Interchangeable Insert Yes
Single Well/Dual Well Single Well
For Stem Diameter 3/8 in, 3/16 in, 1/8 in, (2) 1/4 in
Includes NIST-Traceable Certificate No
Thermocouple Temperature Celsius - Maximum 1480 Degrees C
Thermocouple Temperature Celsius - Minimum 0 Degrees C
RTD Temperature Range 77 Degrees F to 1220 Degrees F ; -25 Degrees C to 660 Degrees C
Overall Height 11.41 in
Interface RS-232
Number of Inserts Included 1
For RTD Type 4-Wire
Voltage 100 to 115V, 230V
Typical Heating Time 15 min (50 Degrees to 660 Degrees C)
Well Depth 5.91 in
For Thermocouple Type Type C, Type E, Type N, Type J, Type K, Type L, Type M, Type R, Type S, Type T, Type U
Process Connections Included RTD, Thermocouple, Transmitter, Reference PRT
Sensor Technology RTD
Thermocouple Temperature Fahrenheit - Maximum 2696 Degrees F
Overall Depth 11.61 in
Stability +/-0.04 Degrees C at 420 Degrees C, +/-0.03 Degrees C at 50 Degrees C, +/-0.05 Degrees C at 660 Degrees C
RTD Temperature Fahrenheit - Minimum 77 Degrees F
Contains California Prop 65 Carcinogen N
Contains California Prop 65 Reproductive Toxicant N
Number of Insert Holes 5
Display Resolution 0.01 Degrees F
Set Point Style Adjustable
Calibrator Weight 17 lb
Power Source Plug-In
RTD Temperature Fahrenheit - Maximum 1220 Degrees F
Temperature Set Points 50 Degrees C, 660 Degrees C
Calibrator Accuracy +/-0.35 Degrees C at 50 Degrees C, +/-0.35 Degrees C at 420 Degrees C, +/-0.5 Degrees C at 660 Degrees C
Insert Hole Diameter 3/16 in, 3/8 in, 1/4 in, 1/8 in
Thermocouple Temperature Fahrenheit - Minimum 32 Degrees F
Insert Type Included A
RTD Temperature Celsius - Maximum 660 Degrees C
Standards NVLAP Accredited
Thermocouple Temperature Range 32 Degrees F to 2696 Degrees F ; -25 Degrees C to 1480 Degrees C
Stabilization Time 10 min
Display Qty 1
Display Sell UOM EA
Overall Width 7.31 in
Manufacturer Part Number 9144-A-P-156
RTD Temperature Celsius - Minimum -25 Degrees C
Typical Cooling Time 25 min (660 Degrees to 100 Degrees C), 35 min (660 Degrees to 50 Degrees C)
Typical Uniformity +/-0.05 Degrees C at 50 Degrees C, +/-0.35 Degrees C at 420 Degrees C, +/-0.5 Degrees C at 660 Degrees C, +/-0.02 Degrees C at 50 Degrees C, +/-0.05 Degrees C at 420 Degrees C, +/-0.10 Degrees C at 660 Degrees C
Mfr. Model # 9144-A-P-156
Description

Drywal Temp Calib, Plug-In, 77, 1220 F

Catalog Page 572