Drywell: 32°F to 2696°F /33°C to 1480°C, 91°F to 662°F /33°C to 350°C, Adj Set Point
Drywell: 32°F to 2696°F /33°C to 1480°C, 91°F to 662°F /33°C to 350°C, Adj Set Point

Product Image

Drywell: 32°F to 2696°F /33°C to 1480°C, 91°F to 662°F /33°C to 350°C, Adj Set Point

Item 33W973 Mfr. Model # 9143-C-P-156
In Stock
$11,545.00 /each
Earn 11545 points with this purchase
Request quantity discount pricing
Compliance & Restrictions
Hazardous Material Contains hazardous waste materials
You're Viewing
Drywell: 32°F to 2696°F /33°C to 1480°C, 91°F to 662°F /33°C to 350°C, Adj Set Point
FLUKE Drywell: 32°F to 2696°F /33°C to 1480°C, 91°F...
Item 33W973
$11,545.00
Customers Also Viewed

No related products found.

Product Details

Catalog Page 572
Brand FLUKE
Includes NIST-Traceable Certificate No
Process Connections Included RTD, Thermocouple, Transmitter, Reference PRT
Thermocouple Temperature Celsius - Maximum 1480 Degrees C
Insert Hole Diameter 1/4 in
Typical Uniformity +/-0.04 Degrees C at 33 Degrees C, +/-0.1 Degrees C at 200 Degrees C, +/-0.2 Degrees C at 350 Degrees C, +/-0.01 Degrees C at 33 Degrees C, +/-0.015 Degrees C at 200 Degrees C, +/-0.02 Degrees C at 350 Degrees C
RTD Temperature Celsius - Minimum 33 Degrees C
Calibrator Accuracy +/-0.2 Degrees C (Display - Full Range)
Number of Insert Holes 4
Set Point Style Adjustable
Interchangeable Insert Yes
Thermocouple Temperature Fahrenheit - Minimum 32 Degrees F
Stabilization Time 10 min
Thermocouple Temperature Celsius - Minimum 0 Degrees C
Single Well/Dual Well Single Well
RTD Temperature Fahrenheit - Minimum 91 Degrees F
For Thermocouple Type Type C, Type E, Type N, Type J, Type K, Type L, Type M, Type R, Type S, Type T, Type U
RTD Temperature Celsius - Maximum 350 Degrees C
For RTD Type 4-Wire
For Stem Diameter (4) 1/4 in
Typical Cooling Time 32 min (350 Degrees to 33 Degrees C), 14 min (350 Degrees to 100 Degrees C)
RTD Temperature Fahrenheit - Maximum 662 Degrees F
Stability +/-0.02 Degrees C at 200 Degrees C, +/-0.03 Degrees C at 350 Degrees C, +/-0.02 Degrees C at 33 Degrees C
Typical Heating Time 5 min (33 Degrees to 350 Degrees C)
Number of Inserts Included 1
Insert Type Included C
Temperature Set Points 350 Degrees C, 30 Degrees C
Thermocouple Temperature Fahrenheit - Maximum 2696 Degrees F
Mfr. Model # 9143-C-P-156
Country of Origin USA (subject to change)
UNSPSC 41113646
Description

Drywall Temperature Calibrator, Field Metrology Well, Fluke 9143, -196 Degrees to 660 Degrees C, 0 Degrees to 1,480 Degrees C, Temperature Set Points 30 Degrees C, 350 Degrees C, Calibration Details NVLAP Accredited Calibration Included, Interface RS-232, Number of Set Points Variable, 11 13/32 in H x 7 5/16 in W x 11 39/64 in D

Catalog Page 572