Drywell: 91°F to 662°F /33°C to 350°C, 91°F to 662°F /33°C to 350°C, Adj Set Point
In Stock
$10,323.00
/each
Earn 10323 points with this purchase
Request quantity discount pricing
You're Viewing
FLUKE Drywell: 91°F to 662°F /33°C to 350°C, 91°F t...
Item KD-0408844
$10,323.00
Customers Also Viewed
No related products found.
Product Details
| Catalog Page | 572 |
| Brand | FLUKE |
| Overall Depth | 11.61 in |
| Display Sell UOM | EA |
| Set Point Style | Adjustable |
| Thermocouple Temperature Celsius - Minimum | 33 Degrees C |
| Insert Type Included | C |
| Typical Cooling Time | 32 min (350 Degrees to 33 Degrees C), 14 min (350 Degrees to 100 Degrees C) |
| Typical Heating Time | 5 min (33 Degrees to 350 Degrees C) |
| Temperature Set Points | 350 Degrees C, 30 Degrees C |
| For Stem Diameter | (4) 1/4 in |
| Power Source | Plug-In |
| Process Connections Included | RTD, Thermocouple, Transmitter |
| RTD Temperature Fahrenheit - Maximum | 662 Degrees F |
| Calibrator Accuracy | +/-0.2 Degrees C (Display - Full Range) |
| Stabilization Time | 10 min |
| Thermocouple Temperature Celsius - Maximum | 350 Degrees C |
| Stability | +/-0.02 Degrees C at 200 Degrees C, +/-0.03 Degrees C at 350 Degrees C, +/-0.02 Degrees C at 33 Degrees C |
| Insert Hole Diameter | 1/4 in |
| Display Qty | 1 |
| RTD Temperature Fahrenheit - Minimum | 91 Degrees F |
| Number of Insert Holes | 4 |
| Thermocouple Temperature Fahrenheit - Maximum | 662 Degrees F |
| RTD Temperature Celsius - Minimum | 33 Degrees C |
| Typical Uniformity | +/-0.04 Degrees C at 33 Degrees C, +/-0.1 Degrees C at 200 Degrees C, +/-0.2 Degrees C at 350 Degrees C, +/-0.01 Degrees C at 33 Degrees C, +/-0.015 Degrees C at 200 Degrees C, +/-0.02 Degrees C at 350 Degrees C |
| For RTD Type | 3-Wire, 4-Wire, 2-Wire, Pt 100 (385) |
| For Thermocouple Type | Type B, Type E, Type J, Type K, Type R, Type S, Type T |
| Thermocouple Temperature Fahrenheit - Minimum | 91 Degrees F |
| Single Well/Dual Well | Single Well |
| Overall Height | 11.41 in |
| Well Depth | 5.91 in |
| Sensor Technology | RTD |
| Overall Width | 7.31 in |
| Contains California Prop 65 Carcinogen | N |
| Display Resolution | 0.01 Degrees F |
| Includes NIST-Traceable Certificate | No |
| Calibrator Weight | 16 lb |
| Manufacturer Part Number | 9143-C-156 |
| Voltage | 100 to 115V, 230V |
| Standards | NVLAP Accredited |
| Contains California Prop 65 Reproductive Toxicant | N |
| Thermocouple Temperature Range | 91 Degrees F to 662 Degrees F ; 33 Degrees C to 350 Degrees C |
| Interchangeable Insert | Yes |
| Number of Inserts Included | 1 |
| RTD Temperature Range | 91 Degrees F to 662 Degrees F ; 33 Degrees C to 350 Degrees C |
| Interface | RS-232 |
| RTD Temperature Celsius - Maximum | 350 Degrees C |
| Mfr. Model # | 9143-C-156 |
Description
Drywal Temp Calib, Plug-In, 91, 662 F