Drywell: 32°F to 2696°F /-196°C to 1480°C, 384.8°F to 1220°F /-196°C to 660°C, Adj Set Point
In Stock
$11,545.00
/each
Earn 11545 points with this purchase
Request quantity discount pricing
Compliance & Restrictions
Hazardous Material
Contains hazardous waste materials
You're Viewing
FLUKE Drywell: 32°F to 2696°F /-196°C to 1480°C, 38...
Item 33W969
$11,545.00
Customers Also Viewed
No related products found.
Product Details
| Catalog Page | 572 |
| Brand | FLUKE |
| Number of Inserts Included | 1 |
| RTD Temperature Celsius - Maximum | 660 Degrees C |
| Process Connections Included | RTD, Thermocouple, Transmitter, Reference PRT |
| Calibrator Accuracy | +/-0.2 Degrees C (Display - Full Range) |
| For Thermocouple Type | Type C, Type E, Type N, Type J, Type K, Type L, Type M, Type R, Type S, Type T, Type U |
| Interchangeable Insert | Yes |
| Insert Hole Diameter | 3/16 in, 3/8 in, 1/4 in, 1/8 in |
| Number of Insert Holes | 5 |
| RTD Temperature Fahrenheit - Minimum | 384.8 Degrees F |
| Includes NIST-Traceable Certificate | No |
| Stabilization Time | 10 min |
| RTD Temperature Fahrenheit - Maximum | 1220 Degrees F |
| Thermocouple Temperature Celsius - Minimum | 0 Degrees C |
| For RTD Type | 4-Wire |
| Temperature Set Points | 350 Degrees C, 30 Degrees C |
| Set Point Style | Adjustable |
| Thermocouple Temperature Celsius - Maximum | 1480 Degrees C |
| Typical Cooling Time | 32 min (350 Degrees to 33 Degrees C), 14 min (350 Degrees to 100 Degrees C) |
| Single Well/Dual Well | Single Well |
| Typical Uniformity | +/-0.04 Degrees C at 33 Degrees C, +/-0.1 Degrees C at 200 Degrees C, +/-0.2 Degrees C at 350 Degrees C, +/-0.01 Degrees C at 33 Degrees C, +/-0.015 Degrees C at 200 Degrees C, +/-0.02 Degrees C at 350 Degrees C |
| RTD Temperature Celsius - Minimum | -196 Degrees C |
| Typical Heating Time | 5 min (33 Degrees to 350 Degrees C) |
| Insert Type Included | A |
| Thermocouple Temperature Fahrenheit - Maximum | 2696 Degrees F |
| For Stem Diameter | 3/8 in, 3/16 in, 1/8 in, (2) 1/4 in |
| Stability | +/-0.02 Degrees C at 200 Degrees C, +/-0.03 Degrees C at 350 Degrees C, +/-0.02 Degrees C at 33 Degrees C |
| Thermocouple Temperature Fahrenheit - Minimum | 32 Degrees F |
| Mfr. Model # | 9143-A-P-156 |
| Country of Origin | USA (subject to change) |
| UNSPSC | 41113646 |
Description
Drywall Temperature Calibrator, Field Metrology Well, Fluke 9143, -196 Degrees to 660 Degrees C, 0 Degrees to 1,480 Degrees C, Temperature Set Points 30 Degrees C, 350 Degrees C, Calibration Details NVLAP Accredited Calibration Included, Interface RS-232, Number of Set Points Variable, 11 13/32 in H x 7 5/16 in W x 11 39/64 in D