Drywell: 32°F to 2696°F /-25°C to 1480°C, -13°F to 302°F /-25°C to 150°C, +/-0.01°C Stability
Drywell: 32°F to 2696°F /-25°C to 1480°C, -13°F to 302°F /-25°C to 150°C, +/-0.01°C Stability

Product Image

Drywell: 32°F to 2696°F /-25°C to 1480°C, -13°F to 302°F /-25°C to 150°C, +/-0.01°C Stability

Item 33W965 Mfr. Model # 9142-E-P-156
In Stock
$14,698.00 /each
Earn 14698 points with this purchase
Request quantity discount pricing
Compliance & Restrictions
Hazardous Material Contains hazardous waste materials
You're Viewing
Drywell: 32°F to 2696°F /-25°C to 1480°C, -13°F to 302°F /-25°C to 150°C, +/-0.01°C Stability
FLUKE Drywell: 32°F to 2696°F /-25°C to 1480°C, -13...
Item 33W965
$14,698.00
Customers Also Viewed

No related products found.

Product Details

Catalog Page 572
Brand FLUKE
Number of Inserts Included 1
Typical Cooling Time 25 min (150 Degrees to -23 Degrees C), 15 min (23 Degrees to -25 Degrees C)
Interchangeable Insert Yes
Process Connections Included RTD, Thermocouple, Transmitter, Reference PRT
Thermocouple Temperature Celsius - Maximum 1480 Degrees C
Insert Type Included E
Stability +/-0.01 Degrees C
Includes NIST-Traceable Certificate No
Stabilization Time 10 min
Number of Insert Holes 5
RTD Temperature Celsius - Maximum 150 Degrees C
Temperature Set Points 150 Degrees C, -25 Degrees C
For Thermocouple Type Type C, Type E, Type N, Type J, Type K, Type L, Type M, Type R, Type S, Type T, Type U
Thermocouple Temperature Celsius - Minimum 0 Degrees C
Typical Uniformity +/-0.05 Degrees C, +/-0.01 Degrees C
For RTD Type 4-Wire
RTD Temperature Fahrenheit - Maximum 302 Degrees F
RTD Temperature Celsius - Minimum -25 Degrees C
Thermocouple Temperature Fahrenheit - Maximum 2696 Degrees F
Typical Heating Time 25 min (-25 Degrees to 150 Degrees C), 23 min (23 Degrees to 150 Degrees C), 16 min (23 Degrees to 140 Degrees C)
Thermocouple Temperature Fahrenheit - Minimum 32 Degrees F
RTD Temperature Fahrenheit - Minimum -13 Degrees F
Single Well/Dual Well Single Well
Set Point Style Adjustable
Calibrator Accuracy +/-0.2 Degrees C (Display - Full Range)
For Stem Diameter 10 mm, 6 mm, 1/4 in, 8 mm, 4 mm
Insert Hole Diameter 6 mm, 3 mm, 4 mm, 6-7/20 mm, 10 mm, 8 mm
Mfr. Model # 9142-E-P-156
Country of Origin USA (subject to change)
UNSPSC 41113646
Description

Drywall Temperature Calibrator, Field Metrology Well, Fluke 9142, -196 Degrees to 660 Degrees C, 0 Degrees to 1,480 Degrees C, Temperature Set Points -25 Degrees C, 150 Degrees C, Calibration Details NVLAP Accredited Calibration Included, Interface RS-232, Number of Set Points Variable, 11 13/32 in H x 7 5/16 in W x 11 39/64 in D

Catalog Page 572