657-600-0865 | contact@KDdepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Drywall Temperature Calibrator: 95°F to 662°F /35°C to 350°C, 95°F to 662°F /35°C to 350°C
Drywall Temperature Calibrator: 95°F to 662°F /35°C to 350°C, 95°F to 662°F /35°C to 350°C

Product Image

Drywall Temperature Calibrator: 95°F to 662°F /35°C to 350°C, 95°F to 662°F /35°C to 350°C

Item KD-0408967 Mfr. Model # 9140-B-156
In Stock
$6,527.00 /each
Earn 6527 points with this purchase
Request quantity discount pricing
You're Viewing
Drywall Temperature Calibrator: 95°F to 662°F /35°C to 350°C, 95°F to 662°F /35°C to 350°C
FLUKE Drywall Temperature Calibrator: 95°F to 662°F...
Item KD-0408967
$6,527.00
Customers Also Viewed

No related products found.

Product Details

Catalog Page 573
Brand FLUKE
Overall Height 3.38 in
Temperature Set Points 350 Degrees C, 35 Degrees C
Thermocouple Temperature Fahrenheit - Minimum 95 Degrees F
Calibrator Accuracy +/-0.5 Degrees C, (holes greater than 1/4" [6.35mm]: +/-1 Degrees C)
Display Qty 1
For Thermocouple Type Type E, Type J, Type K, Type T
Insert Type Included B
Contains California Prop 65 Reproductive Toxicant N
Insert Hole Diameter 9-53/100 mm, 4-19/25 mm, 6-7/20 mm
RTD Temperature Range 95 Degrees F to 662 Degrees F ; 35 Degrees C to 350 Degrees C
Thermocouple Temperature Celsius - Minimum 35 Degrees C
Interface RS-232
For Stem Diameter (2) 3/8 in, (2) 3/16 in, (2) 1/4 in
Number of Insert Holes 6
Overall Width 6 in
Set Point Style Adjustable
RTD Temperature Celsius - Maximum 350 Degrees C
Contains California Prop 65 Carcinogen N
Display Resolution 0.1 Degrees F
Single Well/Dual Well Single Well
Thermocouple Temperature Range 95 Degrees F to 662 Degrees F ; 35 Degrees C to 350 Degrees C
Stability +/-0.03 Degrees C at 50 Degrees C, +/-0.05 Degrees C at 350 Degrees C
Interchangeable Insert Yes
Process Connections Included RTD, Thermocouple
Well Depth 4.9 in
RTD Temperature Fahrenheit - Minimum 95 Degrees F
Voltage 115V AC, 230V AC
Stabilization Time 10 min
RTD Temperature Celsius - Minimum 35 Degrees C
Sensor Technology RTD
Typical Heating Time 12 min (Ambient to 350 Degrees C)
Number of Inserts Included 1
Calibrator Weight 6 lb
Power Source Plug-In
Display Sell UOM EA
Includes NIST-Traceable Certificate Yes
Calibration Certificate Type NIST Traceable
Typical Cooling Time 15 min (350 Degrees to 100 Degrees C)
For RTD Type 3-Wire, 4-Wire, 2-Wire
Standards CE, ROHS, WEEE
Typical Uniformity +/-0.1 Degrees C
Overall Depth 7.75 in
Manufacturer Part Number 9140-B-156
RTD Temperature Fahrenheit - Maximum 662 Degrees F
Thermocouple Temperature Celsius - Maximum 350 Degrees C
Thermocouple Temperature Fahrenheit - Maximum 662 Degrees F
Mfr. Model # 9140-B-156
Description

Drywal Temp Calib, Plug-In, 95, 662 F

Catalog Page 573