657-600-0865 | contact@KDdepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Drywall Temperature Calibrator: 95°F to 662°F /35°C to 350°C, 95°F to 662°F /35°C to 350°C
Drywall Temperature Calibrator: 95°F to 662°F /35°C to 350°C, 95°F to 662°F /35°C to 350°C

Product Image

Drywall Temperature Calibrator: 95°F to 662°F /35°C to 350°C, 95°F to 662°F /35°C to 350°C

Item KD-0408973 Mfr. Model # 9140-A-156
In Stock
$6,527.00 /each
Earn 6527 points with this purchase
Request quantity discount pricing
You're Viewing
Drywall Temperature Calibrator: 95°F to 662°F /35°C to 350°C, 95°F to 662°F /35°C to 350°C
FLUKE Drywall Temperature Calibrator: 95°F to 662°F...
Item KD-0408973
$6,527.00
Customers Also Viewed

No related products found.

Product Details

Catalog Page 573
Brand FLUKE
For Thermocouple Type Type E, Type J, Type K, Type T
Process Connections Included RTD, Thermocouple
Thermocouple Temperature Range 95 Degrees F to 662 Degrees F ; 35 Degrees C to 350 Degrees C
Overall Depth 7.75 in
Voltage 115V AC, 230V AC
Calibration Certificate Type NIST Traceable
Overall Height 3.38 in
Well Depth 4.9 in
Typical Cooling Time 15 min (350 Degrees to 100 Degrees C)
Number of Inserts Included 1
Thermocouple Temperature Fahrenheit - Maximum 662 Degrees F
For Stem Diameter 1/2 in, 3/8 in, 3/16 in, 1/4 in, 1/8 in, 1/16 in
Standards CE, ROHS, WEEE
Display Resolution 0.1 Degrees F
Manufacturer Part Number 9140-A-156
Interface RS-232
Thermocouple Temperature Celsius - Maximum 350 Degrees C
Thermocouple Temperature Celsius - Minimum 35 Degrees C
RTD Temperature Celsius - Minimum 35 Degrees C
Typical Uniformity +/-0.1 Degrees C
Overall Width 6 in
RTD Temperature Celsius - Maximum 350 Degrees C
Single Well/Dual Well Single Well
Insert Hole Diameter 1-3/5 mm, 11-1/10 mm
Typical Heating Time 12 min (Ambient to 350 Degrees C)
Display Qty 1
Number of Insert Holes 5
For RTD Type 3-Wire, 4-Wire, 2-Wire
Insert Type Included A
Set Point Style Adjustable
Contains California Prop 65 Carcinogen N
Includes NIST-Traceable Certificate Yes
Stability +/-0.03 Degrees C at 50 Degrees C, +/-0.05 Degrees C at 350 Degrees C
Interchangeable Insert Yes
Stabilization Time 10 min
Thermocouple Temperature Fahrenheit - Minimum 95 Degrees F
Power Source Plug-In
RTD Temperature Fahrenheit - Minimum 95 Degrees F
Temperature Set Points 350 Degrees C, 35 Degrees C
Display Sell UOM EA
Sensor Technology RTD
RTD Temperature Fahrenheit - Maximum 662 Degrees F
RTD Temperature Range 95 Degrees F to 662 Degrees F ; 35 Degrees C to 350 Degrees C
Calibrator Weight 6 lb
Calibrator Accuracy +/-0.25 Degrees C, (holes greater than 1/4" [6.35mm]: +/-1 Degrees C)
Contains California Prop 65 Reproductive Toxicant N
Mfr. Model # 9140-A-156
Description

Drywal Temp Calib, Plug-In, 95, 662 F

Catalog Page 573