| Brand | DRANETZ |
| Testing Functions | Current, Demand, Energy, Active Energy, Power, Power Factor, Voltage, Amperage, Reactive Power, Apparent Power |
| Contains California Prop 65 Reproductive Toxicant | N |
| Minimum DC Voltage Measured | 40 V |
| Standards | EN 50160: 2010, IEEE 1159: 2009, IEC 61000-4-30 Class A Edition 3, IEEE 519: 2014, IEEE 1459: 2000, IEEE 1453: 2011, IEC 61000-4-7 Class 1: Edition 2 (2008), IEC 61000-4-15: Edition 2 (2010) |
| Maximum DC Voltage Measured | 1,000 V |
| Maximum AC Voltage Measured | 1,000 V |
| Product Powered by Fossil Fuel | N |
| Safety Data Sheet (SDS) Applicable? | N |
| Transient Duration | 32 msec |
| Calibration Frequency | 16/25 Hz, 50/60 Hz |
| Minimum Operating Temperature | 32 Degrees F |
| Display Size | 7 in |
| Includes Software | Yes |
| Tool Length | 10 in |
| Maximum Wattage | 100 TW |
| Voltage Accuracy | +/-0.10% |
| Peak Capture | Yes |
| Power Source | Battery, AC Adapter |
| Maximum AC Current Measured | 300 A |
| IP Rating | IP65 |
| Contains California Prop 65 Carcinogen | N |
| Data Logger | Yes |
| Storage Protection Code | A |
| Tool Width | 8 in |
| Tool Height | 2.8 in |
| Crest Factor | I=3; V=2 |
| Maximum Operating Temperature | 122 Degrees F |
| CAT Safety Rating | CAT III 1000V, CAT IV 600V |
| Digital Memory Capacity | 4 GB |
| Manufacturer Warranty Length | 3 yr |
| RoHS - Restricted Use of Hazardous Substances Directive (RoHS) | N |
| Display Type | Digital |
| Current Accuracy | +/-0.10% |
| Manufacturer Part Number | HDPQ-P-GAMFLEX3PKG |
| Sub-brand | Dranetz |
| Maximum Volt-Amps | 100,000,000 MVA |
| AC Magnitude Calculation | True RMS |
| Display Screen Type | LCD Touchscreen |
| For Phase | Four |
| Display Resolution | 800 x 480 px |
| Features | Automatic Circuit Detection and Feedback on Proper Connection of the Instrument, Arc Flash Safety, Apple and Android Apps with Real Time Metering and Alarm Dashboard, PQ and Energy Dashboard's for Real Time Alarming, Rugged Enclosure with an Easy-to-Grip, Shock Absorbing, Non-Conductive Boot, Automatic Event Categorization, Wire Management in Easel and Hook, Power Supply Cable Retainer, Automatic Setups - PQ, Demand and Energy, Mini-Report - Screen Snapshots, Xml File, Bigger Display for More Productive Local Analysis, Dran-View 7 Power Quality Analysis Software |
| Is this a Hazardous Material Product? | N |
| Data Output Type | Ethernet, Wi-Fi, Bluetooth, USB |
| Freight Class Code | 18 |
| Minimum AC Voltage Measured | 40 V |
| Power Factor | -1 to 0 to 1 |
| Voltage Channels | 4 |
| AC Current Range | 300 A |
| Includes | (4) DRANFLEX300MHB6 Single Phase Flex Probe, (4) Black 25 cm Stackable Jumpers, (4) Black Alligator Clips, Voltage Cable Set 118970-G1, (4) White Alligator Clips, SCC-HDPQ Soft Carry Case, AC Adapter 118317-G1, Dran-View 7 DV7E-PX, (8) 6 ft Measurement Cables: (1) Red, (1) Yellow, (1) Blue, (1) Gray, (4) White |
| Display Qty | 1 |
| Display Sell UOM | EA |
| Sampling Rate | 512 samples/cycle |
| Frequency Rating | 16 to 25 Hz; 42.5 to 69 Hz |
| Should Sales be Restricted by Region? | N |
| Current Channels | 4 |
| Ozone Depleting Substance | N |
| Calibration Certificate Included | NIST Not Traceable |
| Harmonic Capture | 63rd |