Power Quality Analyzer Kit: For Four Phase, CAT III 1000V/CAT IV 600V, IP65, Digital
In Stock
$12,752.21
/each
Earn 12752 points for this item
($127.52 for your next purchase!)
REGISTER NOW TO EARN!
14 days
Request quantity discount pricing
You're Viewing
DRANETZ Power Quality Analyzer Kit: For Four Phase, C...
Mfr # HDPQ-P-GAFLEX3KPKG
$12,752.21
Customers Also Viewed
No related products found.
Product Details
| Brand | DRANETZ |
| Power Factor | -1 to 0 to 1 |
| Standards | EN 50160: 2010, IEEE 1159: 2009, IEC 61000-4-30 Class A Edition 3, IEEE 519: 2014, IEEE 1459: 2000, IEEE 1453: 2011, IEC 61000-4-7 Class 1: Edition 2 (2008), IEC 61000-4-15: Edition 2 (2010) |
| Tool Height | 2.8 in |
| Is this a Hazardous Material Product? | N |
| AC Current Range | 3,000 A |
| Includes Software | Yes |
| Calibration Frequency | 16/25 Hz, 50/60 Hz |
| IP Rating | IP65 |
| Current Accuracy | +/-0.10% |
| AC Magnitude Calculation | True RMS |
| Features | Automatic Circuit Detection and Feedback on Proper Connection of the Instrument, Arc Flash Safety, PQ and Energy Dashboard's for Real Time Alarming, Apple and Android Apps with Real Time Metering and Alarm Dashboard, Rugged Enclosure with an Easy-to-Grip, Shock Absorbing, Non-Conductive Boot, Automatic Event Categorization, Wire Management in Easel and Hook, Power Supply Cable Retainer, Automatic Setups - PQ, Demand and Energy, Mini-Report - Screen Snapshots, Xml File, Bigger Display for More Productive Local Analysis, Dran-View 7 Power Quality Analysis Software |
| Digital Memory Capacity | 4 GB |
| Testing Functions | Current, Demand, Energy, Active Energy, Power, Power Factor, Voltage, Amperage, Reactive Power, Apparent Power |
| Voltage Accuracy | +/-0.10% |
| Calibration Certificate Included | NIST Not Traceable |
| Sub-brand | Dranetz |
| Data Output Type | Ethernet, Wi-Fi, Bluetooth, USB |
| Maximum Volt-Amps | 100,000,000 MVA |
| Manufacturer Warranty Length | 3 yr |
| Maximum AC Current Measured | 3,000 A |
| Tool Length | 10 in |
| Display Size | 7 in |
| Freight Class Code | 18 |
| Tool Width | 8 in |
| Display Sell UOM | EA |
| Includes | (4) Black 25 cm Stackable Jumpers, (4) Black Alligator Clips, DRANFLEX3003XLB24 Three Phase Flex Probe, Voltage Cable Set 118970-G1, (4) White Alligator Clips, DRANFLEX3000XLB24 Single Phase Flex Probe, SCC-HDPQ Soft Carry Case, AC Adapter 118317-G1, Dran-View 7 DV7E-PX, (8) 6 ft Measurement Cables: (1) Red, (1) Yellow, (1) Blue, (1) Gray, (4) White |
| Ozone Depleting Substance | N |
| Frequency Rating | 16 to 25 Hz; 42.5 to 69 Hz |
| Display Resolution | 800 x 480 px |
| Power Source | Battery, AC Adapter |
| Display Type | Digital |
| Manufacturer Part Number | HDPQ-P-GAFLEX3KPKG |
| CAT Safety Rating | CAT III 1000V, CAT IV 600V |
| Current Channels | 4 |
| For Phase | Four |
| Sampling Rate | 512 samples/cycle |
| Should Sales be Restricted by Region? | N |
| Maximum Operating Temperature | 122 Degrees F |
| Contains California Prop 65 Reproductive Toxicant | N |
| Transient Duration | 32 msec |
| Data Logger | Yes |
| Harmonic Capture | 63rd, 127th |
| Display Screen Type | LCD Touchscreen |
| Minimum AC Voltage Measured | 40 V |
| Minimum Operating Temperature | 32 Degrees F |
| Storage Protection Code | A |
| Voltage Channels | 4 |
| Maximum Wattage | 100 TW |
| Display Qty | 1 |
| Contains California Prop 65 Carcinogen | N |
| Maximum AC Voltage Measured | 1,000 V |
| Maximum DC Voltage Measured | 1,000 V |
| Minimum DC Voltage Measured | 40 V |
| Product Powered by Fossil Fuel | N |
| Crest Factor | I=3; V=2 |
| Peak Capture | Yes |
| RoHS - Restricted Use of Hazardous Substances Directive (RoHS) | N |
| Safety Data Sheet (SDS) Applicable? | N |
| Mfr. Model # | HDPQ-P-GAFLEX3KPKG |
Description