Controller: BACnet MS/TP, Fan Coil Units, Includes Onboard Occupancy Sensor, Floating
Controller: BACnet MS/TP, Fan Coil Units, Includes Onboard Occupancy Sensor, Floating

Product Image

Controller: BACnet MS/TP, Fan Coil Units, Includes Onboard Occupancy Sensor, Floating

Manufacturer: KMC CONTROLS
Mfr. Model # BAC-4208CW0001
In Stock
$931.00 Save 25%
$701.11 /each
Earn 701 points for this item ($7.01 for your next purchase!) REGISTER NOW TO EARN!
ETA 3-4 WEEKS
Request quantity discount pricing
You're Viewing
Controller: BACnet MS/TP, Fan Coil Units, Includes Onboard Occupancy Sensor, Floating
KMC CONTROLS Controller: BACnet MS/TP, Fan Coil Units, Inc...
Mfr # BAC-4208CW0001
$701.11
Customers Also Viewed

No related products found.

Product Details

Brand KMC CONTROLS
Mounting Location Wall
Screen Width 1 in
Thermostat Type Low Voltage
Minimum Operating Temperature 32 Degrees F
Overall Height 5-1/8 in
Product Powered by Fossil Fuel N
Display Type Digital
Switch Type SPST
Housing Color White
Backlit Screen Yes
Number of Relay Inputs 0
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Safety Data Sheet (SDS) Applicable? N
Humidification Control No
Maximum Operating Temperature 140 Degrees F
Contains California Prop 65 Carcinogen N
Contact Rating 24V AC
Number of Cooling Stages - Conventional System 1
Network Protocol Compatibility BACnet MS/TP
Overall Width 3-1/2 in
Application Heat or Cool
Terminal Designations -A;+B;AO6;AO7;AO8;BO5;COM;DAT;FAN-H;FAN-L;FAN-M;GND;RBO4;RS;WST
Storage Protection Code A
Mounting Direction Horizontal
Ozone Depleting Substance N
Temperature Sensitivity +/- 0.36 Degrees F
Sensor Location Remote
Number of Cooling Stages - Heat Pump System 1
Dual Transformer Compatible Yes
Freight Class Code 18
Electrical Connection Type Hardwired
Standards UL 916 Energy Management Equipment, SASO PCP Registration KSA R-103260, FCC Class A, Part 15, Subpart B and complies with Canadian ICES-003 Class B, BACnet Testing Laboratory listed, ANSI/ASHRAE BACnet Standard 135-2008
Number of Relay Outputs 6
Compatible System Type Fan Coil Units
Voltage 24V AC
Wireless Hardwired
Number of Heating Stages - Conventional System 1
Temperature Scale Fahrenheit/Celsius
Screen Height 1-1/16 in
Number of Pipes 4, 2
Temperature Adjustment Floating
Occupancy Sensor Includes Onboard Occupancy Sensor
Contains California Prop 65 Reproductive Toxicant N
Control Output Single Stage RTU/Heat Pump with Economizer, Two Stage RTU/Heat Pump with Economizer
Housing Type Flame Retardent Housing
Should Sales be Restricted by Region? N
Includes Backplate
Dehumidification Control No
Lead Wire Gauge 14 ga, 22 ga
Overall Depth 1-1/8 in
Housing Material Plastic
Enclosure Color White
Number of Relay Inputs/Outputs 0/6
Amperage 1 A
Number of Poles 1
Humidification/Dehumidification Control No, No
Sensor Type Thermistor
Manufacturer Part Number BAC-4208CW0001
Remote Control Functions Temperature Control
Sensor Length 33 ft
Is this a Hazardous Material Product? N
Control Type Push Button
Number of Heating Stages - Heat Pump System 1
Frequency 60 Hz, 50 Hz
Key Features Modulating Valves, Modulating Fan
Mfr. Model # BAC-4208CW0001
Description

BACnet MS/TP Tstat, Hardwired, Fan Coil

Catalog Page 0