657-600-0865 | contact@KDdepot.com
Admin Portal USD ($) | EN
Menu
All Products Brands Catalog Wishlist Quote Request
Login Register
Help Contact
Controller: BACnet MS/TP, Fan Coil Units, Includes Onboard Occupancy Sensor, Floating
Controller: BACnet MS/TP, Fan Coil Units, Includes Onboard Occupancy Sensor, Floating

Product Image

Controller: BACnet MS/TP, Fan Coil Units, Includes Onboard Occupancy Sensor, Floating

Item 29VK37 Mfr. Model # BAC-4202CW0001
In Stock
$801.00 /each
Earn 801 points with this purchase
Request quantity discount pricing
You're Viewing
Controller: BACnet MS/TP, Fan Coil Units, Includes Onboard Occupancy Sensor, Floating
KMC CONTROLS Controller: BACnet MS/TP, Fan Coil Units, Inc...
Item 29VK37
$801.00
Customers Also Viewed

No related products found.

Product Details

Brand KMC CONTROLS
Sensor Location Remote
Sensor Type Thermistor
California Prop 65 Reproductive Harm N
Control Type Push Button
Number of Relay Inputs 0
Number of Poles 1
Display Type Digital
Housing Color White
Number of Pipes 4, 2
Compatible System Type Fan Coil Units
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Minimum Operating Temperature 32 Degrees F
Number of Cooling Stages - Heat Pump System 1
Number of Cooling Stages - Conventional System 1
California Prop 65 Cancer N
Enclosure Color White
Mounting Direction Horizontal
Standards UL 916 Energy Management Equipment, SASO PCP Registration KSA R-103260, FCC Class A, Part 15, Subpart B and complies with Canadian ICES-003 Class B, BACnet Testing Laboratory listed, ANSI/ASHRAE BACnet Standard 135-2008
Overall Depth 1-1/8 in
Overall Width 3-1/2 in
Maximum Operating Temperature 140 Degrees F
Screen Height 1-1/16 in
Product Powered by Fossil Fuel N
Dual Transformer Compatible Yes
Number of Relay Inputs/Outputs 0/6
Ozone Depleting Substance N
Remote Control Functions Temperature Control
Lead Wire Gauge 14 ga, 22 ga
Temperature Adjustment Floating
Humidification Control No
Storage Protection Code A
Is this a Hazardous Material Product? N
Screen Width 1 in
Sensor Length 33 ft
Network Protocol Compatibility BACnet MS/TP
Switch Type SPST
Housing Material Plastic
Should Sales be Restricted by Region? N
Freight Class Code 18
Terminal Designations -A;+B;AO6;AO7;AO8;BO5;COM;DAT;FAN-H;FAN-L;FAN-M;GND;RBO4;RS;WST
Application Heat or Cool
Key Features Modulating Valves, Three Speed Fan
Frequency 60 Hz, 50 Hz
Number of Heating Stages - Conventional System 1
Electrical Connection Type Hardwired
Voltage 24V AC
Contact Rating 24V AC
Control Output Single Stage RTU/Heat Pump with Economizer, Two Stage RTU/Heat Pump with Economizer
Number of Relay Outputs 6
Amperage 1 A
Housing Type Flame Retardent Housing
Number of Heating Stages - Heat Pump System 1
Wireless Hardwired
Temperature Scale Fahrenheit/Celsius
Temperature Sensitivity +/- 0.36 Degrees F
Thermostat Type Low Voltage
Dehumidification Control No
Mounting Location Wall
Safety Data Sheet (SDS) Applicable? N
Occupancy Sensor Includes Onboard Occupancy Sensor
Humidification/Dehumidification Control No, No
Includes Backplate
Manufacturer Part Number BAC-4202CW0001
Backlit Screen Yes
Overall Height 5-1/8 in
Mfr. Model # BAC-4202CW0001
Description

BACnet MS/TP Tstat, Hardwired, Fan Coil

Catalog Page 0