Controller: BACnet MS/TP, Fan Coil Units, Compatible with Occupancy Sensor, Floating
Controller: BACnet MS/TP, Fan Coil Units, Compatible with Occupancy Sensor, Floating

Product Image

Controller: BACnet MS/TP, Fan Coil Units, Compatible with Occupancy Sensor, Floating

Item 29VK21 Mfr. Model # BAC-4002CW0001
In Stock
$548.50 /each
Earn 548 points with this purchase
Request quantity discount pricing
You're Viewing
Controller: BACnet MS/TP, Fan Coil Units, Compatible with Occupancy Sensor, Floating
KMC CONTROLS Controller: BACnet MS/TP, Fan Coil Units, Com...
Item 29VK21
$548.50
Customers Also Viewed

No related products found.

Product Details

Brand KMC CONTROLS
Contact Rating 24V AC
Enclosure Color White
Maximum Operating Temperature 140 Degrees F
Product Powered by Fossil Fuel N
California Prop 65 Cancer N
Ozone Depleting Substance N
Frequency 60 Hz, 50 Hz
Programming Capability Not Programmable
Mounting Direction Vertical
Occupancy Sensor Compatible with Occupancy Sensor
Number of Relay Inputs/Outputs 0/4
Housing Color White
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Display Type Digital
Sensor Location Remote
Key Features Modulating Valves, Three Speed Fan
Temperature Adjustment Floating
Is this a Hazardous Material Product? N
Smart Connectivity No Connectivity
Maximum Temperature Control 140 Degrees F
Freight Class Code 18
Number of Heating Stages - Conventional System 2
Safety Data Sheet (SDS) Applicable? N
Humidification Control No
Minimum Temperature Control 32 Degrees F
Application Heat and Cool
Maximum Operating Humidity 90 %
Changeover Type Automatic and Manual
Number of Relay Inputs 0
Number of Pipes 4, 2
Remote Control Functions Temperature Control
Backlit Screen Yes
Overall Height 5-1/8 in
Network Protocol Compatibility BACnet MS/TP
Overall Width 3-1/2 in
Storage Protection Code A
Number of Relay Outputs 4
Dehumidification Control No
Temperature Limiting Yes
Dual Transformer Compatible Yes
California Prop 65 Reproductive Harm N
Should Sales be Restricted by Region? N
Minimum Operating Humidity 10 %
Manufacturer Part Number BAC-4002CW0001
Number of Heating Stages - Heat Pump System 2
Includes Backplate
Minimum Operating Temperature 32 Degrees F
Overall Depth 1-1/8 in
Humidification/Dehumidification Control No, No
Number of Cooling Stages - Heat Pump System 2
Amperage 1 A
Control Type Push Button
Electrical Connection Type Plug-In
Compatible System Type Fan Coil Units
Standards UL 916 Energy Management Equipment, SASO PCP Registration KSA R-103260, BACnet Testing Laboratory listed, FCC Class A, Subpart B and complies with Canadian ICES-003 Class B, Part 15
Temperature Scale Fahrenheit/Celsius
Voltage 24V AC
Housing Material Plastic
Mfr. Model # BAC-4002CW0001
Description

BACnet MS/TP Tstat, Fan Coil Units

Catalog Page 0