BACnet Controller: BACnet MS/TP, Air Handling Units/Fan Coil Units, Floating, Hardwired
BACnet Controller: BACnet MS/TP, Air Handling Units/Fan Coil Units, Floating, Hardwired

Product Image

BACnet Controller: BACnet MS/TP, Air Handling Units/Fan Coil Units, Floating, Hardwired

Item KD-0381918 Mfr. Model # BAC-120036CW
In Stock
$936.00 /each
Earn 936 points with this purchase
Request quantity discount pricing
You're Viewing
BACnet Controller: BACnet MS/TP, Air Handling Units/Fan Coil Units, Floating, Hardwired
KMC CONTROLS BACnet Controller: BACnet MS/TP, Air Handling...
Item KD-0381918
$936.00
Customers Also Viewed

No related products found.

Product Details

Brand KMC CONTROLS
Housing Material Plastic
California Prop 65 Cancer N
Dehumidification Control No
Temperature Scale Fahrenheit/Celsius
Sensor Length 30 ft
Sensor Location Remote
Housing Type Flame Retardent Housing
Standards UL 916 Energy Management Equipment, SASO PCP Registration KSA R-103260, FCC Class A, Part 15, Subpart B and complies with Canadian ICES-003 Class B, BACnet Testing Laboratory listed, ANSI/ASHRAE BACnet Standard 135-2008
Minimum Operating Temperature 32 Degrees F
Application Heat or Cool
Minimum Operating Humidity 0 %
Number of Relay Inputs 0
Overall Height 5-1/2 in
Remote Control Functions Temperature Control
Humidification Control No
RoHS - Restricted Use of Hazardous Substances Directive (RoHS) N
Number of Relay Inputs/Outputs 0/3
Storage Protection Code A
Ozone Depleting Substance N
Display Type Digital
Thermostat Type Low Voltage
Electrical Connection Type Hardwired
Number of Cooling Stages - Heat Pump System 1
Number of Cooling Stages - Conventional System 1
Screen Height 1-1/8 in
Should Sales be Restricted by Region? N
Compatible System Type Fan Coil Units, Air Handling Units
Sensor Type Type II, Thermistor
Number of Relay Outputs 3
Maximum Operating Temperature 125 Degrees F
Temperature Adjustment Floating
Temperature Sensitivity +/- 0.9 Degrees F
Mounting Location Wall
Wireless Hardwired
Number of Heating Stages - Heat Pump System 1
Overall Width 4-3/16 in
California Prop 65 Reproductive Harm N
Is this a Hazardous Material Product? N
Voltage 24V AC
Product Powered by Fossil Fuel N
Terminal Designations -A;+B;AO6;AO7;AO8;BO5;COM;DAT;FAN-H;FAN-L;FAN-M;GND;RBO4;RS;WST
Occupancy Sensor Compatible with Occupancy Sensor
Enclosure Color White
Contact Rating 24V AC
Key Features Modulating Valves, Three Speed Fan
Backlit Screen Yes
Amperage 1 A
Control Type Push Button
Network Protocol Compatibility BACnet MS/TP
Safety Data Sheet (SDS) Applicable? N
Switch Type SPST
Control Output Floating Fan Coil and Zoning, Two RTU/Heat Pump with Optional Economizer
Lead Wire Gauge 14 ga, 22 ga
Freight Class Code 2
Housing Color White
Mounting Direction Horizontal
Dual Transformer Compatible Yes
Number of Pipes 4, 2
Includes Backplate
Humidification/Dehumidification Control No, No
Number of Heating Stages - Conventional System 1
Maximum Operating Humidity 95 %
Overall Depth 1-1/8 in
Manufacturer Part Number BAC-120036CW
Number of Poles 1
Mfr. Model # BAC-120036CW
Description

BACnet MS/TP Tstat, Hardwire, Air Handling

Catalog Page 0