EnviroAlert® EA400-12 Four Zone Digital Environmental Monitor Alarm 12 Volt DC
EnviroAlert® EA400-12 Four Zone Digital Environmental Monitor Alarm 12 Volt DC

Product Image

EnviroAlert® EA400-12 Four Zone Digital Environmental Monitor Alarm 12 Volt DC

Manufacturer: Winland Electronics Inc
Mfr. Model # EA400-12
Model # B508506
In Stock
$329.95 Save 0%
$329.13 /each
Earn 329 points for this item ($3.29 for your next purchase!) REGISTER NOW TO EARN!
Ships from the manufacturer in about 1 business day
Request quantity discount pricing
You're Viewing
EnviroAlert® EA400-12 Four Zone Digital Environmental Monitor Alarm 12 Volt DC
Winland Electronics Inc EnviroAlert® EA400-12 Four Zone Digital Envir...
Mfr # EA400-12
$329.13
Customers Also Viewed

No related products found.

Product Details

Brand Winland Electronics Inc
Mfr. Model # EA400-12
Global Industrial Part # B508506
UPC 082075000963
Color White
Weight 0.55 lb
Length 6 in
Width 4.75 in
Height 1.25 in
Unit of Measure EA
Country of Origin US
Ships Via Parcel
Freight Class 65
Lead Time 1 business day
Returnable Yes
California Prop 65 Warning applies
UNSPSC 77101505
Description

The enviroalert EA400-12 critical-environment monitoring device provides visibility to two environmental zones(areas) ambient temperature and an additional zone(area) to monitor for temperature humidity or water presence. In addition to the local (on device) visual and audible (piezo buzzer required

3RD party buzzer add on) notifications when integrated to a security panel the system allows for the real-time notification of an incident and immediate corrective action.

Features
  • Simultaneous operation of one on-board sensor and one additional external sensor(sold separately) with easy to read LCD display and tamper proof lock setting.

8 event incident memory including time and date with auxiliary output relay for local audible alarm(not included) with alarm silence feature with 10 minute timer and up to 120 minute alarm time delay programable for each zone.

Do not place EA400-12 inside cooler/freezer. Use a wired sensor connected to the EA400-12.

Adjust sensor reading with offset up to 9.0

Power requirements of 12VDC

120MA

No on-board sensor

Sensor dependent low limit and high limit adjustment range of -58 to +302 f (-50 to +150 c)

4 configurable form c (spdt) alarm output relays (n.o./n.c.) and 1 non-configurable form c (spdt) auxiliary alarm output relay (n.o./n.c.)