Soft Start: 208-600V AC, 140 A Output Current, With Bypass, IP20/NEMA 1, 60/50 Hz, 110V AC
In Stock
$3,368.00
/each
Earn 3368 points with this purchase
Request quantity discount pricing
You're Viewing
SCHNEIDER ELECTRIC Soft Start: 208-600V AC, 140 A Output Current...
Mfr # ATS22C14S6U
$3,368.00
Customers Also Viewed
No related products found.
Product Details
| Brand | SCHNEIDER ELECTRIC |
| Manufacturer Part Number | ATS22C14S6U |
| Number of Inputs - Analog | 1 |
| Control Voltage | 110V AC |
| Output Power [Merch] | 40 hp Output Power @ Three-Phase - 208V ; 50 hp Output Power @ Three-Phase - 230V ; 100 hp Output Power @ Three-Phase - 460V ; 125 hp Output Power @ Three-Phase - 575V |
| Storage Protection Code | A |
| yy DELETE - Output Power | 50 hp @ 3 Phase, 230V AC, 100 hp @ 3 Phase, 460V AC, 125 hp @ 3 Phase, 575V AC, 40 hp @ 3 Phase, 208V AC |
| Stop Time - Minimum | 10 sec, 0 sec |
| Input Voltage | 208-600V AC |
| zz DELETE - Item | Soft Start |
| Product Type | Soft Start |
| Output Power @ Three-Phase - 230V | 50 hp |
| Ramp Time - Minimum | 0 sec |
| Display Qty | 1 |
| Stop Time - Maximum | 1 sec, 60 sec |
| Enclosure Rating | NEMA 1, IP20 |
| Display Sell UOM | EA |
| Protects | Phase Failure Line, Thermal Protection Motor, Thermal Protection Starter |
| Ozone Depleting Substance | N |
| Application | Pumps, Fans |
| Phase | Three |
| Contains California Prop 65 Carcinogen | N |
| RoHS - Restricted Use of Hazardous Substances Directive (RoHS) | N |
| Start Type | Torque Control Start |
| Includes Communication Port | Yes |
| Is this a Hazardous Material Product? | N |
| Overall Width | 5.91 in |
| Safety Data Sheet (SDS) Applicable? | N |
| yy DELETE - Stop Time | 1 to 60 sec, 0 to 10 sec |
| Output Current | 140 A |
| Function Type | Start/Stop |
| Output Power @ Three-Phase - 208V | 40 hp |
| Freight Class Code | 13 |
| Bypass Design | With Bypass |
| Output Power @ Three-Phase - 460V | 100 hp |
| Standards | CSA Certified, GOST, EN/IEC 60947-4-2, C-tick, CCC, UL Listed |
| Contains California Prop 65 Reproductive Toxicant | N |
| Display Type | LED |
| yy DELETE - Ramp Time | 0 to 20 Sec., 0 to 40 Sec. |
| Communication Protocols Supported | Modbus |
| zz DELETE - Output Voltage | 208 to 600V AC |
| Ramp Time - Maximum | 40 sec, 20 sec |
| EnvironmentallyPreferable_Indicator | N |
| Overall Height | 14.02 in |
| Should Sales be Restricted by Region? | N |
| Overall Depth | 9.04 in |
| Output Power @ Three-Phase - 575V | 125 hp |
| Product Powered by Fossil Fuel | N |
| Frequency | 60/50 Hz |
| yy DELETE - Input and Output Types | 2 (NC/NO) Relay Outputs, 1 PTC Probe Analog Input, 3 Logic Inputs |
| Sub-brand | Altistart(R) 22 |
| Mfr. Model # | ATS22C14S6U |
Description
Soft Start, 208 to 600V AC, 140 A