Soft Start: 600V AC, 66 A Output Current, With Bypass, NEMA 1, 60/50 Hz, Three Phase, 24V DC
In Stock
$6,454.00
/each
Earn 6454 points with this purchase
Request quantity discount pricing
You're Viewing
EATON Soft Start: 600V AC, 66 A Output Current, Wit...
Mfr # S811+N66N3S
$6,454.00
Customers Also Viewed
No related products found.
Product Details
| Brand | EATON |
| zz DELETE - Output Voltage | 600V AC |
| EnvironmentallyPreferable_Indicator | N |
| Output Current | 66 A |
| Starting Torque | 0% to 83% |
| Overall Height | 7.36 in |
| Ramp Time - Minimum | 0 sec |
| RoHS - Restricted Use of Hazardous Substances Directive (RoHS) | N |
| zz DELETE - Item | Soft Start |
| Overall Width | 2.66 in |
| Number of Inputs - Analog | 1 |
| Product Powered by Fossil Fuel | N |
| Output Power @ Three-Phase - 460V | 40 hp |
| yy DELETE - Output Power | 40 hp @ 3 Phase, 480V AC, 50 hp @ 3 Phase, 575V AC, 15 hp @ 3 Phase, 200V AC, 20 hp @ 3 Phase, 240V AC |
| Output Power @ Three-Phase - 480V | 40 hp |
| Frequency | 60/50 Hz |
| Ozone Depleting Substance | N |
| Enclosure Rating | NEMA 1 |
| Protects | Motor Overload, Jam, Stall, Pole Over Temperature, Phase Loss, Phase Imbalance, Ability to Alarm Without Tripping for Critical Situations, Ability for Advance Communications for Critical Load Monitoring |
| Output Power @ Three-Phase - 208V | 15 hp |
| Safety Data Sheet (SDS) Applicable? | N |
| Manufacturer Part Number | S811+N66N3S |
| Number of Outputs - Digital | 9 |
| Bypass Design | With Bypass |
| Contains California Prop 65 Carcinogen | N |
| Display Sell UOM | EA |
| Stop Time - Maximum | 60 sec |
| Product Type | Soft Start |
| Function Type | Start/Stop |
| Ramp Time - Maximum | 180 sec |
| Is this a Hazardous Material Product? | N |
| Application | Constant and Variable Torque |
| Should Sales be Restricted by Region? | N |
| Output Power [Merch] | 15 hp Output Power @ Three-Phase - 208V ; 20 hp Output Power @ Three-Phase - 230V ; 20 hp Output Power @ Three-Phase - 240V ; 40 hp Output Power @ Three-Phase - 460V ; 40 hp Output Power @ Three-Phase - 480V ; 50 hp Output Power @ Three-Phase - 575V |
| Display Qty | 1 |
| Control Voltage | 24V DC |
| Output Power @ Three-Phase - 240V | 20 hp |
| Overall Depth | 6.5 in |
| Standards | UL 508, CSA 22.2-14-1995, GB14048, IEC/EN 60947-4-2 |
| Input Voltage | 600V AC |
| yy DELETE - Input and Output Types | Analog Input, (9) Function Based Digital Inputs/Outputs, (3) 6A Relay Outputs |
| Contains California Prop 65 Reproductive Toxicant | N |
| Output Power @ Three-Phase - 575V | 50 hp |
| Number of Outputs - Relay | 3 |
| Communication Protocols Supported | Modbus RTU |
| yy DELETE - Ramp Time | 0 to 180 sec. |
| Output Power @ Three-Phase - 230V | 20 hp |
| Includes Communication Port | Yes |
| Number of Inputs - Digital | 9 |
| Stop Time - Minimum | 0 sec |
| Storage Protection Code | A |
| Freight Class Code | 18 |
| Phase | Three |
| yy DELETE - Stop Time | 0 to 60 sec |
| Sub-brand | Soft Starts |
| Mfr. Model # | S811+N66N3S |
Description